background image

 

Maximal3FDV/5FDV/7FDV Series (PTC) Installation Guide 

- 9 -

Fig. 3 - 

Maximal3FDV, Maximal5FDV, and Maximal7FDV

Power Supply

Board

NC  C  NO  NC C  NO

AC FAIL

BAT FAIL

TRIGGER

AC DC

AC1

EOL

NO

GND

SUPERVISED

RESET

+AUX-

-  BAT  

+-

  DC  

+

L     G     N

OFF - 24V
ON - 12V

ON

OUTPUT 1     OUTPUT 2         OUTPUT 3         OUTPUT 4          OUTPUT 5        OUTPUT 6         OUTPUT 7        OUTPUT 

8

NC  C  NO COM NC C NO COM  NC  C  NO COM NC C NO COM  NC  C  NO COM NC C NO COM  NC  C NO COM NC C NO CO

M

 IN  GND IN GND IN GND IN GND

IN  GND IN GND IN  GND IN GND

1            2           3          

4

5           6           7           

8

 INPUT

TRIGGER

10A 250V

+INP-  T + RET-

NO  C   NC

FACP            INTERFACE

Power   Control

-      +      -      +

F1                   F2                  F3                   F4                   F5                   F6                   F7

                   F8

MAIN

TRG

FACP

1  2  3  

4

1  2  3  

4

ONON

1  2  3  

4

1  2  3  

4

ONON

OUTPUT 1     OUTPUT 2         OUTPUT 3         OUTPUT 4          OUTPUT 5        OUTPUT 6         OUTPUT 7        OUTPUT 

8

NC  C  NO COM NC C NO COM  NC  C  NO COM NC C NO COM  NC  C  NO COM NC C NO COM  NC  C NO COM NC C NO CO

M

 IN  GND IN GND IN GND IN GND

IN  GND IN GND IN  GND IN GND

1            2           3          

4

5           6           7           

8

 INPUT

TRIGGER

10A 250V

+INP-  T + RET-

NO  C   NC

FACP            INTERFACE

Power   Control

-      +      -      +

F1                   F2                  F3                   F4                   F5                   F6                   F7

                   F8

MAIN

TRG

FACP

1  2  3  

4

1  2  3  

4

ONON

1  2  3  

4

1  2  3  

4

ONON

  

Optional 

Rechargeable

Stand-by Battery

-   BAT   +

CAUTION: When power supply board is set for 12VDC

use only one (1) 12VDC stand-by battery.

Connect red battery lead to

the terminal marked [+ BAT]

and to the [positive (+)]

terminal of the battery. 

Connect black battery lead to

terminal marked [BAT –]

and to the [negative (–)]

terminal of the battery.

Input 220VAC, 50/60Hz

Line

Neutral

Tamper Switch

Optional Rechargeable

Stand-by Battery

Optional Rechargeable

Stand-by Battery

CAUTION: When power supply board is set for

12VDC use only one (1) 12VDC stand-by battery.

Keep power-limited wiring separate from non power-limited. 

Use minimum 0.25" spacing. 

12AH Rechargeable batteries are the largest batteries that 

can fit in this enclosure. An external battery enclosure 

must be used if using the 40AH or 65AH batteries.

Ground

Lug

Fig. 3b

Fig. 3a

Tamper Switch

(provided)

To Access Control Panel or

UL Listed Reporting Device

Edge of

Enclosure

Enclosure

Содержание Maximal 3FDV

Страница 1: ...utputs Maximal5FDV 12VDC 8 6A Sixteen 16 PTC protected outputs Maximal7FDV 24VDC 9 2A Sixteen 16 PTC protected outputs Rev SFDV031115 More than just power TM Installing Company ________________ Servic...

Страница 2: ...LED Diagnostics pg 6 Access Power Controller LED Diagnostics pg 6 Power Supply Board Terminal Identification pg 6 Access Power Controller Terminal Identification pg 7 Power Supply Board Stand by Batt...

Страница 3: ...0 19 26 4 12VDC 4 6A or 24VDC 5 2A 16 2 1A 2 5 5A 250V 10A 32V 10A 250V Maximal5FDV 9 7 13 2 10 03 13 2 8 6A 16 2 1A 2 5 5A 250V 15A 32V 10A 250V Maximal7FDV 19 8 26 4 20 28 26 4 9 2A 16 2 7A 2 5 6 3A...

Страница 4: ...Terminal Identification pg 7 Power Supply Board Stand by Battery Specifications pg 7 Power Supply Board Output Voltage Settings pg 7 Access Power Controller Typical Application Diagram pg 8 FACP Optio...

Страница 5: ...For latching hook up refer to Fig 9 pg 11 c FACP Signaling Circuit input trigger Connect the positive and negative from the FACP signaling circuit output to the terminals marked INP Connect the FACP E...

Страница 6: ...ill illuminate All outputs selected for Fire Alarm Disconnect will activate releasing locking devices Note All outputs OUT 1 OUT 8 must be in a normal de energized condition prior to testing When the...

Страница 7: ...er factory connected These terminals are paralleled to the Control terminals Control These terminals are paralleled to the Power terminals These terminals can be connected to an external access contro...

Страница 8: ...ND 4 IN GND 5 IN GND 6 IN GND 7 MAIN IN GND 8 LED2 LED3 LED4 LED5 LED6 LED7 LED8 J2 FACP NC C NO COM OUTPUT 3 NC C NO COM OUTPUT 4 NC C NO COM OUTPUT 5 NC C NO COM OUTPUT 6 NO C NC INP T RET NC C NO C...

Страница 9: ...8 INPUT TRIGGER 10A 250V INP T RET NO C NC FACP INTERFACE Power Control F1 F2 F3 F4 F5 F6 F7 F8 MAIN TRG FACP 1 2 3 4 1 2 3 4 O N O N 1 2 3 4 1 2 3 4 O N O N Optional Rechargeable Stand by Battery BAT...

Страница 10: ...ctions must be made employing suitable gauge CM or FPL jacketed wire or equivalent substitute Optional UL Listed battery enclosure must be mounted adjacent to the power supply via Class 1 wiring metho...

Страница 11: ...O C NC FACP INTERFACE JUMPER N C DRY TRIGGER INPUT TRG NO C NC FACP INTERFACE FACP N C TRIGGER INPUT N C RESET SWITCH JUMPER TRG FACP N O TRIGGER INPUT TRG FACP NO C NC FACP INTERFACE N C RESET SWITCH...

Страница 12: ...4mm 8 9 226 1mm 8 4 213 4mm 19 482 6mm 4 101 6mm 1 25 4mm 7 5 190 5mm 5 127mm 26 660 4mm 1 5 38 1mm 1 0 25 4mm 6 25 158 8mm 8 5 215 9mm 7 5 190 5mm 10 254mm 26 660 4mm 1 25 31 8mm 7 177 8mm 7 177 8mm...

Отзывы: