Altronix HubWayLD8CD Скачать руководство пользователя страница 7

 

HubWayLD Active Unit 

- 7 -

(ON) 

16 

PICTURE  GAIN  PICTURE  GAIN  PICTURE  GAIN  PICTURE  GAIN  PICTURE  GAIN  PICTURE  GAIN  PICTURE  GAIN  PICTURE  GAIN 

PICTURE  GAIN  PICTURE  GAIN  PICTURE  GAIN  PICTURE  GAIN  PICTURE  GAIN  PICTURE  GAIN  PICTURE  GAIN  PICTURE 

AC POWER 

GAIN 

15 

14 

13 

12 

11 

10 

CH 1-4 

CH 5-8 

28VAC 

OFF 

24VAC 

+ DATA --

1-8

+ DATA --

9-16

10 

11 

12 

CH 9-12 

28VAC 

OFF 

24VAC 

13 

14 

15 

16 

CH 13-16 

1.625"

41.28mm

17.625"

447.67mm

8.5"

215.9mm

19.125"

485.78mm

0.75"

19.05mm

Rack Mount Chassis Mechanical Drawing & Dimensions

 (H x W x D approximate)

:

1.625” x 19.125” x 8.5” (41.275mm x 486mm x 215.9mm)

TOP & BOTTOM

REAR

FRONT

Fig. 5
Illuminated master power disconnect circuit breaker:
  •  OFF position Circuit breaker tripped – Switch not illuminated.
  •  RESET (ON) position – Switch illuminated.

The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient
magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important 
operating and maintenance (servicing) instructions in the literature accompanying the appliance.

CAUTION: To reduce the risk of electric shock do not open enclosure. There
are no user serviceable parts inside. Refer servicing to qualified service personnel.

Содержание HubWayLD8CD

Страница 1: ...Transceiver Hub with Integral Camera Power Transceiver Hub with Integral Camera Power Includes eight 8 UL Listed Accessory Includes sixteen 16 UL Listed Accessory HubWayAv Video Balun Combiners HubWayAv Video Balun Combiners HubWayLD83CD HubWayLD163CD UL Listed eight 8 Channel Active UTP UL Listed sixteen 16 Channel Active UTP Transceiver Hub with Integral Camera Power Transceiver Hub with Integra...

Страница 2: ...ed Accessory HubWayAv Video Balun Combiners for 24VAC Cameras HubWayLD163CD HubWayLD16CD with sixteen 16 UL Listed Accessory HubWayDv Video Balun Combiners for 12VDC Cameras Agency Listings UL Listed for Commercial CCTV Equipment UL 2044 CUL Listed CSA Standard C22 2 No 1 04 Audio Video and Similar Equipment Data RS422 RS485 data inputs Power Individually selectable 24VAC or 28VAC power outputs wi...

Страница 3: ...D and each camera routed through the HubSat4D 9 Set illuminated master power disconnect circuit breaker to the RESET ON position Fig 5 pg 7 and measure the output voltage at the power output terminals of each Video Balun Combiner Figs 2b 2d pg 5 before powering each camera to ensure proper operation and avoid possible damage HubWayAv HubWayAv2 Terminals marked AC POWER Figs 2a 2b 2e pg 5 HubWayDv ...

Страница 4: ...n optional HubSat4D any of these inputs can be utilized for data transmission to PTZ s 1f BNC Connector Video outputs to head end equipment DVR 1d Voltage Output Selector Switch Selects 24VAC 28VAC OFF for each output 1b Channels 1 4 Channels 5 8 Channels 9 12 Channels 13 16 CAT 5 or higher structured cable from optional HubSat4D enables video transmission from up to four 4 cameras 1i LED s 1 16 V...

Страница 5: ...des and PIN Configurations HubWayAv HubWayAv2 passes AC voltage from pins 4 5 7 8 to terminals marked AC Power Fig 3 pg 5 HubWayDv HubWayDvi converts AC voltage to DC voltage from pins 4 5 7 8 to terminals marked 12VDC Fig 3 pg 5 VIDEO BALUN COMBINER CAT5 DATA POWER AC VIDEO HubWayAv VIDEO AC Power to Camera Data to Camera Data to Camera Green Power LED 12VDC Power to Camera Red Power LED Wire Con...

Страница 6: ...o Balun Combiner HubWayAv Video Balun Combiner Fixed Camera Fixed Camera Max video 3000 ft PTZ Camera Video Power HubWayDv Dvi Video Balun Combiner CAT 5 24VAC 28VAC Camera Power Provided by HubSat4D Video Data Power Outdoor NEMA Rated Power Supply Outdoor PTZ Camera 115VAC Input 50 60Hz HubWayAv or HubWayDv Dvi Video Balun Combiner Monitor Rear Front 1 2 3 4 CH 1 4 CH 5 8 28VAC OFF 24VAC DATA 1 8...

Страница 7: ... TOP BOTTOM REAR FRONT Fig 5 Illuminated master power disconnect circuit breaker OFF position Circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude t...

Страница 8: ... when installing the unit vertically Rack Mount Installation 1 Remove and discard factory installed screws from both sides of rack chassis Fig 6a 2 Install mounting brackets A on the left and right side of rack chassis using the four 4 flat head screws B included Fig 6b 3 Place unit into desired EIA 19 rack position and secure with mounting screws not included Fig 6c Fig 8 Fig 7 Shelf Installation...

Отзывы: