- 8 - 

eFlowNBV - Power Supply/Chargers

eFlow Power Supply/Chargers can be

Controlled and Monitored while Reporting

Power/Diagnostics from Anywhere

over the Network...

LINQ2 Mounts Inside any eFlow Enclosure

LINQ2 - Network Communication Module

LINQ2 provides remote IP access to real-time data from eFlow power 
supply/chargers to help keep systems up and running at optimal 
levels . It facilitates fast and easy installation and set-up, minimizes 
system downtime, and eliminates unnecessary service calls, which 
helps reduce Total Cost of Ownership (TCO) - as well as creating a 
new source of Recurring Monthly Revenue (RMR) . 

LINQ2 

Features:

-  UL Listed in the U .S . and Canada .
-  Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN .
-  Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, 
  input trigger state change, output state change and unit temperature .
-  Access control and user managment: Restrict read/write, Restrict users to specific resources
-  Two (2) integral network controlled Form “C” Relays .
-  Three (3) programmable input triggers: Control relays and power supplies via external hardware sources .
-  Email and Windows Dashboard notifications
-  Event log tracks history .
-  Secure Socket Layer (SSL) .
-  Programmable via USB or web browser - includes operating software and 6 ft . USB cable .

LINQ2 Module

Network

Connection:

Installation,

Programming

and Monitoring

L

G

N

NC

C

NO

NC

C

NO

BA

T F

AIL

AC F

AIL

AC

AC1

DC

TRIGGER EO

L

SUPER

VISE

D

disable

enable

2 hr

.

1 min

.

AC DELAY   

SHUTDOWN

O N

eFlow

Power

Supply/Charger

Содержание eFlow Series

Страница 1: ...1418 Power Supply Charger Boards Installation Guide Models Include eFlow3NBV 12VDC or 24VDC 2A eFlow4NBV 12 or 24VDC 4A eFlow6NBV 12 or 24VDC 6A eFlow102NBV 12VDC 10A eFlow104NBV 24VDC 10A More than j...

Страница 2: ...ew pg 3 Specifications pg 3 Features pg 3 Stand by Specifications pg 4 Installation Instructions pg 5 eFlowNBV configuration pg 5 Wiring pg 6 Maintenance pg 6 LED Diagnostics pg 6 Terminal Identificat...

Страница 3: ...y Backup Built in charger for sealed lead acid or gel type batteries Automatic switch over to stand by battery when AC fails Transfer to stand by battery power is instantaneous with no interruption Fi...

Страница 4: ...urg Applications 4 hr Stand by 15 min Alarm Fire Applications 24 hr Stand by 5 min Alarm Access Control Applications Stand by 7AH 0 4A 6A 10 Mins 6A 12AH 1A 6A 0 3A 6A 35 Mins 6A 40AH 6A 6A 1 2A 6A Ov...

Страница 5: ...uxiliary device connection this output will not be affected by Low Power Disconnect or Fire Alarm Interface Connect device to terminals marked AUX Fig 1f pg 5 6 For Access Control applications batteri...

Страница 6: ...AC 50 60Hz to these terminals L to hot N to neutral G to ground Fig 1a pg 5 DC Fig 1h pg 5 eFlow3NBV 12VDC or 24VDC 2A continuous output power limited output eFlow4NBV 12VDC or 24VDC 4A continuous out...

Страница 7: ...x is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty Ma...

Страница 8: ...te control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery status service input trigger state change output st...

Отзывы: