7. Connect devices to terminals marked [1P - 1N through 4P - 4N] on PD4/PD4CB board,
[1P - 1N through 8P - 8N] on PD8/PD8CB, [1P - 1N through 16P - 16N] on PD16W/PD16WCB/PD16CB board,
carefully observing correct polarity
(Figs. 1-4, pgs. 4-6)
.
Terminals marked [1P - 16P] are positive (+) and terminals marked [1N - 16N] are negative.
8. Green LED will illuminate when unit is powered.
9. Upon completion of wiring, secure enclosure door with screws (supplied).
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
Terminal Identification:
Power Supply Board
Terminal Legend
Function/Description
AC/AC
Low voltage AC input.
+ DC --
6VDC-15VDC output.
PD4UL/PD4ULCB - Distribution Module
1P - 4P
Positive DC outputs.
1N - 4N
Negative DC outputs.
PD8UL/PD8ULCB - Distribution Module
1P - 8P
Positive DC outputs.
1N - 8N
Negative DC outputs.
PD16W/PD16WCB/PD16CB - Distribution Module
1P - 16P
Positive DC outputs.
1N - 16N
Negative DC outputs.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated “DANGEROUS VOLTAGE” within the products enclosure that may be of sufficient
magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are
no user serviceable parts inside. Refer servicing to qualified service personnel.
- 3 -