ALTV2432220 Series

Overview:

Altronix ALTV2432220 Series CCTV Power Supplies provide 24VAC or 28VAC distributed via thirty-two (32) 
fuse or PTC protected outputs for powering CCTV cameras, heaters and other video accessories.

Thirty-Two (32) Output ALTV2432220 Reference Chart:

Altronix 
Model Number

Output 

Voltage

Total 

Output 

Current 

(Power)

Number of

Outputs

PTC Protected

Outputs

(auto-resettable)

Fuse Protected

Outputs

Output Current

(max per output)

220VAC

50/60Hz

Input Current

ALTV2432220

24VAC

8A

32

P

3.5A

1.5A

28VAC

7A

ALTV2432CB220

24VAC

8A

P

2.5A

28VAC

7A

ALTV2432350220

24VAC

14A

P

3.5A

28VAC

12.5A

ALTV2432350CB220

24VAC

14A

P

2.5A

28VAC

12.5A

ALTV2432600220

24VAC

28A

P

3.5A

3A

28VAC

25A

ALTV2432600CB220

24VAC

28A

P

2.5A

28VAC

25A

Specifications:

Installation Instructions:

1.  Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes 
 

in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place 

 

the enclosure’s upper keyholes over the two upper screws; level and secure. Mark the position of the lower 

 

two holes. Remove the enclosure. Drill the lower holes and install the fasteners. Place the enclosure’s upper 

 

keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws 

 

(Enclosure Dimensions, pg. 8). Secure enclosure to earth ground. 

2.  Turn main switch on the unit OFF (Figs. 1-3, pgs. 4-6).
3.  All units are factory set for 24VAC operation. 
 

For 28VAC operation, adjust unit prior to mounting and applying power as follows:

 

Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and the 

 

yellow wire [24V] is connected to the terminal marked [S].

4.  Connect unswitched AC circuit (220VAC, 50/60Hz) as follows: Green branch wire (ground) connects to 
 

the terminal marked     , Line connects to the terminal marked [L], and Neutral connects to the terminal 

 

marked [N] of the Inlet Appliance Connector. (Figs. 1-5, pgs. 4-6)

 

   

 

Use 18 AWG or larger for all power connections.

5.  Turn main switch on the unit to the ON (RESET) position (Figs. 1-3, pgs. 4-6).
6.  Measure output voltage before connecting devices. This helps avoiding potential damage.
 

CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting 

 

the output voltage.

Agency Listing:

•  CE European Conformity. 

Input:

•  220VAC, 50/60Hz.

Output:

•  Thirty-two (32) fuse or PTC protected outputs. 
•  24VAC or 28VAC supply current.
•  Outputs are rated @ 3.5A (fused) or 2.5A (PTC).
•  Surge suppression.

Features:

•  Secondary fuse rated @ 10A/250V.
•  AC power LED.
•  Power ON/OFF switch.
•  Spare fuses provided.
  (all models w/primary and/or secondary fuses).

Enclosure Dimensions:

  13.5” x 13” x 3.25”
  (342.9mm x 330.2mm x 82.6mm).

Illuminated 

Power Switch

PTCs 

used on

ALTV2432CB220

Input 220VAC,

50/60Hz, 1.5A

4A

250V

N

PD16W

XFMR INPUT

SP

P

N

3

1 2

4 5 6 7 8

PROTECTED

OUTPUTS

OUTPUTS

COMMON

11

10

9

12 13

P

16

15

14

N

3.5A 250V

N

PD16W

XFMR INPUT

SP

P

N

3

1 2

4 5 6 7 8

PROTECTED

OUTPUTS

OUTPUTS

COMMON

11

10

9

12 13

P

16

15

14

N

3.5A 250V

Содержание ALTV2432220

Страница 1: ...Fuse Protected Outputs Thirty two 32 PTC Protected Outputs ALTV2432350220 ALTV2432350CB220 24VAC 14A 350VA or 24VAC 14A 350VA or 28VAC 12 5A 350VA 28VAC 12 5A 350VA Thirty two 32 Fuse Protected Outpu...

Страница 2: ...unit OFF Figs 1 3 pgs 4 6 3 All units are factory set for 24VAC operation For 28VAC operation adjust unit prior to mounting and applying power as follows Change the wire position so that the black wir...

Страница 3: ...e unit to rain or moisture This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes Terminal Identification PD16W PD16WCB...

Страница 4: ...6 15 14 N 3 5A 250V N PD16W XFMR INPUT S P P N 3 1 2 4 5 6 7 8 PROTECTED OUTPUTS OUTPUTS COMMON 11 10 9 12 13 P 16 15 14 N 3 5A 250V Fig 1 ALTV2432220 and ALTV2432CB220 24VAC or 28VAC fused or PTC pro...

Страница 5: ...5 14 N 3 5A 250V N PD16W XFMR INPUT S P P N 3 1 2 4 5 6 7 8 PROTECTED OUTPUTS OUTPUTS COMMON 11 10 9 12 13 P 16 15 14 N 3 5A 250V Fig 2 ALTV2432350220 and ALTV2432350CB220 24VAC or 28VAC fused or PTC...

Страница 6: ...12 13 P 16 15 14 N 3 5A 250V N PD16W XFMR INPUT S P P N 3 1 2 4 5 6 7 8 PROTECTED OUTPUTS OUTPUTS COMMON 11 10 9 12 13 P 16 15 14 N 3 5A 250V PTCs used on ALTV2432600CB220 24VAC or 28VAC fused or PTC...

Страница 7: ...ALTV2432220 Series 7 Notes...

Страница 8: ...y Made in U S A IIALTV2432220 Series E10R MEMBER 1 40 36mm 1 40 36mm 4 85 123mm 4 85 123mm 1 40 36mm 1 40 36mm 5 10 130mm 5 10 130mm 13 0 330mm 5 10 130mm 6 5625 167mm 1 20 31mm 1 20 31mm 1 20 31mm 3...

Отзывы: