background image

ALTV2416UL Series 

CCTV Power Supplies

Installation Guide

Models Include:

 

ALTV2416ULX 

 

ALTV2416ULCBX

 

-  24VAC @ 7 amp (170VA) 

 

-  24VAC @ 7 amp (170VA)

    or 28VAC @ 6 amp (170VA). 

 

   or 28VAC @ 6 amp (170VA).

  -  Sixteen (16) Fuse Protected Outputs.   

-  Sixteen (16) PTC Protected Outputs.

 

ALTV2416300UL  

• 

ALTV2416300ULCB 

 

-  24VAC @ 12.5 amp (300VA) 

 

-  24VAC @ 12.5 amp (300VA)

    or 28VAC @ 10 amp (280VA). 

 

   or 28VAC @ 10 amp (280VA).

  -  Sixteen (16) Fuse Protected Outputs.   

-  Sixteen (16) PTC Protected Outputs.

 

ALTV2416300ULM  

• 

ALTV2416300ULCBM 

 

-  24VAC @ 12.5 amp (300VA) 

 

-  24VAC @ 12.5 amp (300VA)

    or 28VAC @ 10 amp (280VA). 

 

   or 28VAC @ 10 amp (280VA).

  -  Sixteen (16) Fuse Protected Outputs.   

-  Sixteen (16) PTC Protected Outputs.

 

ALTV2416600UL 

 

ALTV2416600ULCB

 

-  24VAC @ 25 amp (600VA) 

 

-  24VAC @ 25 amp (600VA)

    or 28VAC @ 20 amp (560VA). 

 

   or 28VAC @ 20 amp (560VA).

  -  Sixteen (16) Fuse Protected Outputs.   

-  Sixteen (16) PTC Protected Outputs.

Rev. 040506

Содержание ALTV2416300UL

Страница 1: ... 12 5 amp 300VA or 28VAC 10 amp 280VA or 28VAC 10 amp 280VA Sixteen 16 Fuse Protected Outputs Sixteen 16 PTC Protected Outputs ALTV2416300ULM ALTV2416300ULCBM 24VAC 12 5 amp 300VA 24VAC 12 5 amp 300VA or 28VAC 10 amp 280VA or 28VAC 10 amp 280VA Sixteen 16 Fuse Protected Outputs Sixteen 16 PTC Protected Outputs ALTV2416600UL ALTV2416600ULCB 24VAC 25 amp 600VA 24VAC 25 amp 600VA or 28VAC 20 amp 560V...

Страница 2: ...Specifications Installation Instructions Wiring methods shall be in accordance with the National Electrical Code NFPA 70 NFPA 72 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Mount unit in desired location Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure Install two upper fasteners and screws in ...

Страница 3: ...istribution board marked PD to OFF position for models ALTV2416ULX or ALTV2416ULCBX Figs 1 2 pgs 4 5 Set power disconnect circuit breaker to OFF position for all other models Figs 3a 8a pgs 6 10 8 Connect devices to terminals marked 1P 1N through 8P 8N on PD8 board Figs 1 4 pgs 4 7 Figs 7 8 pgs 9 10 or terminals marked 1P 1N through 16P 16N on PD16W PD16WCB board Figs 5 6 pg 8 carefully observing ...

Страница 4: ...C or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 Class 1 Outputs Fig 1 ALTV2416ULX The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation po...

Страница 5: ...0 Hz White Lead Black Lead XFMR XFMR non power limited non power limited Black Lead Ground Primary In line Fuse 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC configuration Class 2 Not Wet Class 3 Wet 28VAC configuration Class 1 24VAC config...

Страница 6: ...M M O N P O W E R O U T P U T S P F U S E D P O W E R O U T P U T S 1 2 3 4 5 6 7 8 D1 INPUT N P S R1 LED MAIN FUSE MAIN FUSE Illuminated Power Disconnect Circuit Breaker with manual reset Class 1 Outputs 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 throu...

Страница 7: ... 115VAC input 60 Hz XFMR Ground Connected to Door non power limited non power limited Illuminated Power Disconnect Circuit Breaker with manual reset 24VAC configuration Class 2 Not Wet Class 3 Wet 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24V...

Страница 8: ...s P N XFMR N P S XFMR Input 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 P N Illuminated Power Disconnect Circuit Breaker with manual reset Fig 5 ALTV2416300ULM Transformer underneath power supply board Illuminated Power Disconnect Circuit Breaker with manual reset P N N P S XFMR Input common outputs protected outputs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 N P Fig 6 ALTV2416300ULCBM Fig 5a Fig 6a ...

Страница 9: ...MR Black Lead 115VAC input 60 Hz Ground Connected to Door non power limited non power limited non power limited MAIN FUSE MAIN FUSE Illuminated Power Disconnect Circuit Breaker with manual reset Class 1 Outputs 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2...

Страница 10: ...Hz Ground Connected to Door non power limited non power limited non power limited Illuminated Power Disconnect Circuit Breaker with manual reset 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC or 28VAC output 1 Follow same procedure using terminals 2P N through 8P N outputs 2 through 8 24VAC configuration Class 2 Not Wet Class 3 Wet XFMR 24...

Страница 11: ...1 1 00 1 75 1 00 1 25 1 25 8 13 1 00 1 00 1 25 8 13 7 25 7 25 1 00 3 85 0 60 1 00 3 85 1 00 0 60 7 25 3 63 1 25 0 90 0 60 3 85 0 60 0 90 8 13 Enclosure Dimensions for ALTV2416300ULM ALTV2416300ULCBM 8 5 H x 7 5 W x 3 75 D ...

Страница 12: ...th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A II1ALTV2416ULSeries G16L Enclosure Dimensions for ALTV2416ULX ALTV2416ULCBX ALTV2416300UL ALTV2416300ULCB ALTV2416600UL ALTV2416600ULCB 13 5 H x 13 W x 3 5 D ...