background image

 

- 2 - 

AL300ULXJ

Overview:

Altronix AL300ULXJ power supply converts a 115VAC, 60Hz input to a 12VDC or 24VDC output.

Features:

Agency Listings:

•  UL Listed: 
 UL294
 

Access Control Systems.

 UL603 

Power Supplies for use with 

   

Burglar-Alarm Systems. 

 UL1069   Hospital Signaling and 
   

Nurse Call Equipment. 

 UL1481   Power Supplies for Fire
    

Protective Signaling Systems.

•  cUL Listed: 
  CSA Standard C22.2 No.205-M1983,
  Signal Equipment.
• CSFM - California State Fire Marshal Approved.
•  NFPA 72 Compliant 
  (Fire-Protective Signaling Service).

Input:

•  Input 115VAC, 60Hz, 3.5A.
•  Input fuse rated @ 5A/250V.

Output:

•  Class 2 Rated power-limited output.
•  12VDC or 24VDC selectable output.
  Fire Alarm applications outputs are “Special 
 Applications” 

(refer to Appendix A, pg. 6).

  Burglar Alarm Applications (UL 603):
  12VDC = 10VDC-13.2VDC.
  24VDC = 20VDC-26.4VDC.

Output 

(cont’d)

:

•  2.5A total supply current at 12VDC or 24VDC. 
  Do not exceed total output rating of 2.5A @ 
  12VDC or 24VDC per unit.
•  Output fuse rated @ 15A/32V.
•  Filtered and electronically regulated output(s).
•  Short circuit and thermal overload protection.

LED Indicators:

•  AC input, DC output and Battery LED indicators.

Battery Backup:

•  Built-in charger for sealed lead acid or 
  gel type batteries.
•  Automatic switch over to stand-by battery 
  when AC fails.
•  Maximum charge current 0.7A.
•  Zero voltage drop when switched over to 
  battery backup.

Supervision:

•  AC fail supervision (form “C” contacts). 
•  Low battery and battery presence supervision
  (form “C” contacts).

Additional Features:

•   Power supply, enclosure, cam lock and battery leads.
•  For grey enclosure add “G” suffix to the part number.

Power Supply Output Specifications:

Output VDC

Switch Position

12VDC

SW1 - ON (Fig. 1c)

24VDC

SW1 - OFF (Fig. 1c)

Stand-by Specifications 

(total current shown)

:

Output

4 hr. of Stand-by and

5 Minutes of Alarm

24 hr. of Stand-by and

5 Minutes of Alarm

60 hr. of Stand-by and

5 Minutes of Alarm

12VDC / 40AH Battery

Stand-by = 2.5A

Alarm = 2.5A

Stand-by = 1.0A

Alarm = 2.5A

Stand-by = 300mA

Alarm = 2.5A

24VDC / 12AH Battery

Stand-by = 200mA

Alarm = 2.5A

24VDC / 40AH Battery

Stand-by = 2.5A

Alarm = 2.5A

Stand-by = 1.0A

Alarm = 2.5A

Stand-by = 300mA

Alarm = 2.5A

ON

OFF - 24V

ON - 12V

Содержание AL300ULXJ

Страница 1: ...More than just power TM Rev 102612 AL300ULXJ Power Supply Charger Installation Guide Altronix Corp 140 58th St Brooklyn NY For a grey enclosure add a G suffix to the part number...

Страница 2: ...2V Filtered and electronically regulated output s Short circuit and thermal overload protection LED Indicators AC input DC output and Battery LED indicators Battery Backup Built in charger for sealed...

Страница 3: ...his helps avoiding potential damage When servicing the unit AC mains should be removed 5 Connect devices to the terminals marked DC Fig 1 pg 5 6 For Access Control applications batteries are optional...

Страница 4: ...lly energized when AC power is present Contact rating 1A 28VDC AC Fail condition will report approximately within one 1 minute after loss of AC To delay report for 6 hours cut jumper J1 on the Power S...

Страница 5: ...ction against risk of electric shock and fire hazard replace fuse with the same type and rating Do not expose to rain or moisture CAUTION Optional rechargeable stand by batteries must match the power...

Страница 6: ...Thermal Supervisory Relay 15 45 2312 24TB Photoelectric 0 12 50 2412 12 volt Photoelectric 0 12 77 2424 Photoelectric 0 10 41 2451 Photoelectric 0 10 39 2451TH with B402B Base Photoelectric 0 10 39 2...

Страница 7: ...AL300ULXJ 7 Notes...

Страница 8: ...MEMBER 4 5 114 3mm 1 25 31 75mm 1 25 31 8mm 1 0 25 4mm 1 0 25 4mm 1 0 25 4mm 1 5 38 1mm 1 5 38 1mm 1 5 38 1mm 1 5 38 1mm 1 5 38 1mm 8 5 215 9mm 18 0 457 2mm 18 0 457 2mm 18 0 457 2mm 6 0 152 4mm 2 75...

Отзывы: