- 2 -
AL168CB Series Installation Guide
Overview:
Altronix AL168CB Series Multi-Output Power Supplies provide 16VAC/18VAC distributed via eight (8) auto-
resettable PTC protected outputs for powering multiple security system or access control panels.
Eight (8) Output AL168 Reference Chart:
Altronix
Model Number
Output
Voltage
Total
Output
Current
(A)
Number
of PTC
Protected
Outputs
Output
Current
(max per
output)
Main Fuse
Ratings
on Board
115VAC
50/60Hz
Input
Current
AL168CB
16VAC
6A
8
2.5A
10A/250V
0.9A
18VAC
5.5A
AL168175CB
16VAC
10A
15A/250V
1.45A
AL168300CB
16VAC
18A
15A/32V
2.7A
18VAC
16A
AL168300CBM
16VAC
18A
18VAC
16A
AL168600CB
16VAC
40A
6A
Two (2)
15A/32V
5.4A
18VAC
36A
Specifications:
Installation Instructions:
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes
in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place
the enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower
two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s
upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws
(Enclosure Dimensions, pgs. 10-12)
. Secure enclosure to earth ground.
2. Turn OFF main switch (except AL168CB)
(Figs. 2-5, pgs. 5-8)
.
3. All units are factory set for 16VAC operation.
For 18VAC operation adjust unit prior to mounting and applying power as follows:
Change the wire position so that the black wire [18V] is connected to the terminal marked [P] and the
yellow wire [16V] is connected to the terminal marked [S].
4. Connect AC power to the black and white flying leads of the transformer(s)
(Figs. 1-5, pgs. 4-8)
.
Use 18 AWG or larger for all power connections.
5. Measure output voltage before connecting devices. This helps avoiding potential damage.
Terminals marked [1P] - [8P] are positive of the same polarity.
Input:
• 115VAC, 50/60Hz.
Output:
• Eight (8) PTC protected outputs.
• 16VAC or 18VAC supply current.
• Outputs are rated @ 2.5A.
• Surge suppression.
Features:
• AC power LED indicator.
• Illuminated power disconnect circuit breaker with
manual reset (except AL168CB).
• Unit maintains camera synchronization.
• Ease of installation saves time and
eliminates costly labor.
Enclosure Dimensions:
AL168CB and AL168175CB:
8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm)
AL168300CBM:
8.5” x 7.5” x 3.875”(215.9mm x 191mm x 98.4mm)
AL168300CB
and
AL168600CB:
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm)
Содержание AL168 Series
Страница 9: ...AL168CB Series Installation Guide 9 Notes...