![Alton VICTORIAN CHELTENHAM Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/alton/victorian-cheltenham/victorian-cheltenham_instruction-manual_2912747006.webp)
6
Side Assembly
Begin by laying out the components for your 2 extension sides flat on the ground as the diagram
below shows. Use the table below to help identify the components with the part numbers and sizes.
First of all drill pilot holes through the bottom of each mortise on the cill section (diagram 4, page 9).
Then slot each glazing bar into the mortise holes. These are designed as a tight fit so you may need
help with this or maybe use a solid object to push against. Once firmly in position fix with the 50mm
screw. Now slot the eaves rail into position. There is no need to fix this yet as it is done at a later
stage.
4
Part
Number
Size
(mm)
Qty
EV0176 2520 2
EV0423 2564 1
EV0501 1588 6
8ft Extension
Part Name
Cill
Eaves Bar L
Glazing Bar
Eaves Bar R
EV0422 2564 1
Righ
t han
d eav
es ba
r ext
erna
l face
Diagram 1
EV04
22
EV0489
EV0422
EV0489
EV0489
Internal – Right hand
Dia. 1
EV0176
EV0176
EV0423
EV0489
Dia. 2
Dia. 3
Internal – Left hand side
EV0489
EV0489
Square cut
(no joint)
Dia. 4
Square cut
(no joint)
Содержание VICTORIAN CHELTENHAM