1-34
American-Lincoln Technology
ATS 46/53 Troubleshooting Guide
SQUEEGEE & VACUUM CIRCUITS
Conditions necessary for circuits to work
1.
Battery Voltage
2.
Key switch on
3.
CB-7, CB-8 & CB-11 closed
4.
Squeegee switch in lower position
5.
Squeegee solenoid (7) energized
6.
Engine running
Squeegee lock up solenoid (10) holds squeegee up when engine is turned off.
Vacuum motors will run between 38v-42volts with engine RPM at2000.
Squeegee switch works like this:
1.
Squeegee switch (TOP) position-Squeegee up & vac. off.
2.
Squeegee switch (MIDDLE) position-Squeegee up vac. on.
3.
Squeegee switch (BOTTOM) position-Squeegee down & vac. on.