American-Lincoln
1 - 17
91 WS
POST OPERATION CHECKLIST
After stopping the machine perform these post operation checks.
1. Check sweeping brooms for wear or damage.
2. Check all flaps for wear, damage or adjustment.
3. Close the supply valve on the LP cylinder. Check the fuel level and install a filled cylinder if needed.
~3. Fill the fuel tank.
*3. Charge the batteries.
4. Perform the scheduled maintenance according to the service chart.
- = LP powered machines only.
~= Gasoline powered machines only.
* = Battery powered machines only.
BATTERY CHARGING INSTRUCTIONS
Charge the batteries at the end of each day or when the battery condition meter indicates low battery voltage.
The batteries need to be charged when the needle stays in the “red” zone while the machine is being operated.
When charging batteries, only use the quick disconnect provided. Use the quick disconnect to insure correct
polarity.
Check the liquid level in the batteries a least once a week and add water when low. Use only distilled water. Fill
the batteries after charging the batteries to prevent electrolyte from spilling over on to the tops of the batteries
during the charging process.
WARNING
The use of an extension cord with the charger should be avoided. Risk of fire and electrical shock is possible if the
wrong type or size extension cord is used. If an extension cord must be used, only use a three conductor number
12 AWG cord with ground, properly wired, in good electrical condition and keep it as short as possible. Locate all
cords so that they cannot be stepped on, tripped over, or otherwise subjected to damage or stress.
WARNING
Verify that the AC power source to which the charger is to be connected is capable of supplying the current
specified on the charger nameplate.
WARNING
Keep all charger ventilation holes at least 2 inches away from walls or other objects. Do not allow vent holes to
become obstructed.
WARNING
Do not operate charger that has been damaged or shows physical signs of damage. Have charger serviced by a
qualified professional repair person.
WARNING
Lead acid batteries generate gases which can cause an explosion. Keep sparks and flames away from batteries.
NO SMOKING. Charge batteries only in area with good ventilation and always leave the top cover open while
charging batteries. Do not disconnect the charger from the batteries before disconnecting the AC power cord.
Disconnecting the battery cable with the charger plugged in could cause an explosion.
OPERATING INSTRUCTIONS
Содержание 91WS
Страница 47: ...1 46 American Lincoln Technology 91 WS NOTES ...
Страница 60: ...American Lincoln 2 13 91 WS C1177 1 H61 H141 H14 H65 H145 H44 H33 H125 MAIN BROOM ARMS EXPLODED VIEW ...
Страница 78: ...American Lincoln 2 31 91 WS H12 H9 H46 H26 H15 H103 H34 H43 C1180 9604 CONTROL PANEL BATTERY EXPLODED VIEW ...
Страница 80: ...American Lincoln 2 33 91 WS H103 H15 H27 H26 H46 H43 H34 H144 H9 H12 C1181 CONTROL PANEL GAS EXPLODED VIEW ...
Страница 83: ...2 36 American Lincoln 91 WS NOTES ...
Страница 85: ...2 38 American Lincoln Technology 91 WS NOTES ...