MN-35947
•
Rev 22
•
10/22
•
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
•
53
Inspection Checklist
Customer
Signature: ___________________________________________________
Technician Signature: ___________________________________________________
12-Month Inspection Checklist
Inspect and Tighten - Door hinges and lower hinge pin bolt
Inspect and Tighten - Door handle
If there is a smoker, inspect the smoke element for visual signs of deformation, cracks or breaks (replace as needed)
Review - Error code history
Note the soft ware version (update if not current)
Record - Water pressure (static & dynamic)
Record - Line voltage across all lines
Record - Line voltage to ground on each line
Record - Amperage across all three legs (when heating)
Function test all components (list components)
For ovens shipped to New Zealand or Australia, inspect the backflow preventer check valve per AS/NZ3500.1 and AS/NZ3500.2
Component Failure and Replacement
Summarize any component failure(s) that may have occurred during this month.
Unit Information
Business
Name:
_______________________________________
Model
Number:
_______________________________________
Serial
Number:
______________________________
12-Month Inspection Start Date: ______________________________