CT ExpRESS
INSTALLATION MANUAL •
12 .
m o B i l e e q u i p m e n t r e s t r a i n t
i n s t a l l a t i o n
any appliance that is not furnished with a
power supply cord but includes a set of casters,
stand with casters, or a stacked configuration
must be installed with a tether. adequate means
must be provided to limit the movement of this
appliance without depending on or transmitting
stress to the electrical conduit. The following
requirements apply:
1.
casters must be a maximum height of 6" (152mm).
2.
Two of the casters must be the locking type.
3.
such appliances must be installed with the use
of a flexible connector secured to the
building structure.
4.
each of the stacked appliances must be
installed with the use of a flexible connector
secured to the building structure. a single wall
anchor may be used.
a mounting connector for a restraining device is
located on the top right back panel of the appliance
chassis or on an oven stand, approximately
18" (457mm) from the floor. a flexible connector is
not supplied by nor is it available from the factory.
w a r n i n g
risk of electric shock.
Appliance must be secured
to building structure.
Mounting connector for
restraining device