    • InstallatIon

W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450  USA

 

PHONE:  262.251.3800 •  800.558.8744 

usa

/

caNada

   

FaX:    262.251.7067 • 800.329.8744 

u

.

s

.

a

ONly

www

.

altO

-

sHaaM

.

cOM

Shown with ExpressTouch control 

and optional hand sprayer 

Содержание Combitherm CT EXPRESS 4-10ESi

Страница 1: ...Steamer CT Express 4 10esi 4 10ESiVH Installation W164 N9221 Water Street P O Box 450 Menomonee Falls Wisconsin 53052 0450 USA PHONE 262 251 3800 800 558 8744 usa canada FAX 262 251 7067 800 329 8744 u s a only www alto shaam com Shown with ExpressTouch control and optional hand sprayer ...

Страница 2: ...ESi 8 Specifications 4 10ESiVH 9 Electrical Connection 10 Mobile Equipment Restraint 12 Water Quality Requirement 13 Water Connections 14 Hand Held Spray Hose 15 Water Drainage 16 Ventless Hood Information 17 Ventless Hood Filters 18 Installation Checklist 19 Error Codes 20 Wire Diagrams Always refer to the wire diagram s included with the unit for most current version Warranty Original Equipment ...

Страница 3: ...move the appliance from the carton or crate note do not discard the carton and other packaging material until you have inspected the unit for hidden damage and tested it for proper operation 2 read all instructions in this manual carefully before initiating the installation of this appliance do noT discard This Manual This manual is considered to be part of the appliance and is to be provided to t...

Страница 4: ...this appliance operating instructions and warnings must be read and understood by all operators and users 3 any troubleshooting guides component views and parts lists included in this manual are for general reference only and are intended for use by qualified technical personnel 4 This manual should be considered a permanent part of this appliance This manual and all supplied instructions diagrams...

Страница 5: ...per or with a power means of exhaust provisions shall be made to allow the equipment to operate only when the damper is open to a position to properly vent the appliance and when the power means of exhaust is in operation in accordance with NFPA 54 commonwealth of massachusetts only ventilation requirements A steam ventilation hood is mandatory for the operation of the oven The ventilation hood mu...

Страница 6: ... damage to the oven building or cause personal injury to personnel MINIMUM CLEARANCE REQUIREMENTS left side 4 152mm minimum 18 457mm service access recommended 20 508mm from heat producing equipment right side 4 102mm back 4 102mm for plumbing bottom 4 102mm for air movement top 20 508mm for air movement NOTE Additional clearance is needed for service access A minimum distance of 18 inches is stro...

Страница 7: ...ts are located in front of the legs and must not be damaged The left and right fork should be located between the front and back legs and located as close to the legs as possible Lift the unit high enough to remove the wooden pallet Have a second person hold the unit to prevent unit from shifting When moving the unit drive slowly keep it low to the ground and use extreme caution caution TO PREVENT...

Страница 8: ...ck of the oven for plumbing connections q Allow a 20 inch 500mm clearance at the top of the oven for free air movement and for the steam vent s located at the top q Do not install the oven adjacent to heat producing equipment such as fryers broilers etc Heat from such appliances may cause damage to the controls of the Combitherm Minimum clearance recommended 20 inches 500mm Place the Combitherm ov...

Страница 9: ...0 Triple Guard Replacement Filter for each oven FI 28744 Fry Basket 12 x 20 325mm x 530mm BS 26730 Grilling Grate 12 x 20 325mm x 530mm sh 26731 Poultry Roasting Rack 6 poultry capacity fits in full size pan SH 23000 Scale Free CE 27889 citrus based non corrosive deliming product case four 4 lb bottles 4 lb bottle makes 10 gallons Service Start Up Check specify as required available through the al...

Страница 10: ...nT BACK 4 102mm BOTTOM 4 102mm For air MoVeMenT an additional water supply is required for the optional hand held spray hose dimensions h x w x d EXTERIOR 33 1 2 x 20 7 16 x 35 3 4 850mm x 517mm x 906mm EXTERIOR WITH OPTIONAL HAND SPRAYER 33 1 2 x 23 7 16 x 35 3 4 850mm x 593mm x 906mm 4 10esi Installation requirements Oven must be installed level Hood installation is required Water supply shut of...

Страница 11: ...m TOP 20 508mm For air MoVeMenT BACK 4 102mm BOTTOM 4 102mm For air MoVeMenT an additional water supply is required for the optional hand held spray hose dimensions h x w x d EXTERIOR 45 1 2 x 20 3 4 x 37 13 16 1156mm x 527mm x 960mm EXTERIOR WITH OPTIONAL HAND HELD SPRAY HOSE 45 1 2 x 23 3 4 x 37 13 16 1156mm x 603mm x 960mm 4 10esiVH Installation requirements Oven must be installed level Oven ho...

Страница 12: ...istant cord like h05rn or h07rn or equivalent must be used 1 An electrical wiring diagram is located behind the control panel on the left side of the oven 3 Phase units must be branch circuit protected with proper ampacities in accordance with the wiring diagram A dedicated 30 Amp breaker is required 2 Wire size for the main incoming power to the unit must match the minimum size listed in the spec...

Страница 13: ... MUST be adequately grounded in accordance with local electrical codes or in the absence of local codes with the current edition of the National Electrical Code ANSI NFPA No 70 In Canada all electrical connections are to be made in accordance with CSA C22 1 Canadian Electrical Code Part 1 or local codes Top Back of unit note where local codes and ce regulatory requirements apply appliances must be...

Страница 14: ...wo of the casters must be the locking type 3 Such appliances must be installed with the use of a flexible connector secured to the building structure 4 Each of the stacked appliances must be installed with the use of a flexible connector secured to the building structure A single wall anchor may be used A mounting connector for a restraining device is located on the top right back panel of the app...

Страница 15: ...mitted to provide as much information as possible to help protect the investment made in this equipment a combiguard water Filtration system can be purchased as an option for installation on the combitherm oven This filter when properly installed maintained and combined with the required levels of steam generating equipment maintenance will help lessen the affect water has on metal surfaces it wil...

Страница 16: ...onnection on oven Water Filter Install water intake filter Figure 1 one suggested method of installation note unions or FleXible lines should be used to allow For oven movement when being serviced or cleaning is needed reFer to Figure 1 above For ProPer intaKe locations CombiGuard FI 23014 shown alto shaam now offers an improved water filtration system for combitherm The combiguard triple guard wa...

Страница 17: ... opening Fasten the valve bracket using the 2 self drilling screws 2 Using the sprayer hanger as a template for placement and a 28 drill bit 0 14 diameter drill three holes at the upper front side of unit same side as door opening Fasten the sprayer hanger using the 3 self drilling screws 3 Connect the sprayer hose to the valve and place the sprayer in the hanger 4 Continue to connect an incoming ...

Страница 18: ...itive gradient away from the Combitherm oven and not more than 12 inches 305mm before an air gap NOTE In the U S A this equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the Food Drug Administration FDA If several units are to be connected to one drain pipe the dimen...

Страница 19: ... filter door latch Using a coin or screwdriver turn to open reverse procedure to close and latch Hood and oven will not operate unless this is closed properly operation 1 Turn the ventless hood power knob ON 2 Indicator light will illuminate 3 Wait five seconds then press the Combitherm oven power ON 2 1 Timed Latching Mechanism In order to evacuate steam and grease laden air from the oven interio...

Страница 20: ...replaced using the filter track in the metal back plate provided with the hood FI 24114 2 Grease Filter Cleaning frequency should be based on oven usage with a maximum of two weeks between cleaning if the oven is used for non grease laden products or steam applications only Grease laden products require cleaning frequency of at least once a week Remove the grease filter by pulling it straight out ...

Страница 21: ...YES NO if no explain ____________________________ is a filter system installed on this unit YES NO store has seen this recommendation YES NO Signature of Store Representative ___________________________________________ control board connections operation ExpressTouch With the Power on press the Settings Key to access software version Simple Control As unit is powered on software version will appea...

Страница 22: ...l probe Faulty or plugged dual solenoid valve assembly Wiring or connection issue No output to dual solenoid from relay board Relay board high voltage is not operating e02 Control Temperature High Relay board surface temperature too high Wiring or connection issue Cooling fan on Relay board assembly is not operating Cooling Fan on display board is not operating Main Cooling fan is not operating Co...

Страница 23: ...e receptacle defective B11 Single point Core Temperature probe receptacle wires disconnected e21 N6 Cavity probe Fault Cavity temperature probe defect or disconnected N6 Oven Cavity Temperature probe defective N6 Oven Cavity Temperature connection problem e22 B10 Core Temperature probe Multipoint Fault Multipoint core temperature probe defect or disconnected B10 Multipoint Core Temperature probe d...

Страница 24: ...shut off Low water pressure Generator drain cap missing or loose Generator drain pump is not sealing Generator drain pump elbow leaking Faulty or scaled water level probe Faulty or plugged dual solenoid valve assembly Wiring or connection issue No output to dual solenoid from relay board e53 Fan Motor High Temperature Fan motor too hot Exhaust hood is not operating properly Check LED flashes on the...

Страница 25: ...able connections mentioned below Ribbon cable defective Relay board low voltage connector defective Display board connector defective e98 RB is in Cesius and DB is in Fahrenheit Conflict of unit configuration in the setup menu Relay board and Data board do not match use setup menu to change format e99 RB is in Fahrenheit and DB is in Cesius Conflict of unit configuration in the setup menu Relay board ...

Страница 26: ...robe Single Point Fault HACCP only Yes Yes No No No No e21 N6 Cavity Probe Fault Yes Yes BOILER UNITS ONLY No No No e22 B10 Core Temp Probe Fault Yes Yes BY TIME ONLY BY TIME ONLY BY TIME ONLY BY TIME ONLY e23 B4 Boiler Probe Fault Yes No No No No No e24 B5 Bypass Probe Fault Yes Yes No No Yes No e25 B3 Condenser Probe Fault Yes Yes Yes No To 356 F 180 C No e26 N8 Boiler Safety Temperature Probe F...

Страница 27: ...E OF WATER NOT MEETING ALTO SHAAM S MINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY Water quality and required maintenance of steam generating equipment is the responsibility of the owner operator The installation and use of Alto Shaam s CombiGuard Water Filtration System is highly recommended 6 Damage caused by use of any cleaning agent other than Alto Shaam s Combitherm Oven Cleaner incl...

Страница 28: ...n claim with the carrier and attach copies of all supporting paperwork We will continue our policy of assisting our customers in collecting claims which have been properly filed and actively pursued We cannot however file any damage claims for you assume the responsibility of any claims or accept deductions in payment for such claims Record the model and serial number of the appliance for easy ref...