Alto-Shaam CH-75 Скачать руководство пользователя страница 7

Operation and Care Manual #861

6

TROUBLE

POSSIBLE CAUSE

REMEDY

Unit does not operate.

Insufficient electric power unit.

Check power source.

Defective plug or cord.

Check and repair if necessary.

Power switch defective.

Replace.

Cooking temperature not correct.

Cook thermostat out of calibration.

Calibrate.

Holding temperature not correct.

Hold thermostat out of calibration.

Calibrate.

Timer runs down, but oven will not

Timer not de-energizing cook circuit.

Replace timer.

go into HOLD.

Cook thermostat erratic — will not

Cook thermostat.

Replace thermostat.

hold calibration.

Hold thermostat erratic — will not

Hold thermostat.

Replace thermostat.

hold calibration.

Oven goes from cooking temperature

Hold thermostat.

Replace hold thermostat.

to cold.

Oven will not go into cook cycle

Timer or contactor.

With timer turned ON, line voltage

when timer and cook thermostat are ON.

should appear across term.  2 and 3 
of timer.  If not, replace timer.

If line voltage does appear across term.
2 and 3 of timer, it should also appear 
across holding coil of contactor.

If line voltage does appear across 
holding coil, and it won’t close its 
contacts, replace contactor.

It takes too long to cook.

Heating element open, resulting in

Replace element.

(Temperature O.K.)

low wattage.

Cannot control temperature but

Heating element grounded.

Replace element.

thermostats check O.K.

TROUBLE SHOOTING CHECKLIST

O P T I O N S   &   A C C E S S O R I E S

DESCRIPTION

ITEM

Bumper Guards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5221

Carving Holders

—Prime Rib Holder . . . . . . . . . . . . . . . . . . . . . . . HL-2635

—Ship Round Holder . . . . . . . . . . . . . . . . . . . . . . . . . 4459

Casters, 5" (127mm). . . . . . . . . . . . . . . . . . . . . . . . . . 4007

Cylinder Key Lock  . . . . . . . . . . . . . . . . . . . . . . . LK-22567

Drip Pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1062

Legs, 6" (152mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5205

DESCRIPTION

ITEM

Pocket Thermometer, °F . . . . . . . . . . . . . . . . . . . . . TH-3300

Pocket Thermometer, °C. . . . . . . . . . . . . . . . . . . . . TH-3412

Security Panel & Key Lock . . . . . . . . . . . . . . . . . . . . . 14374

Shelf, Stainless Steel

—Rib Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SH-2743

—Wire, Flat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SH-2324

Stacking Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4011

Thermostat, 250°F (120°C)  Limit . . . . . . . . . . . . . . TT-3058

Содержание CH-75

Страница 1: ...r e e t P O B o x 4 5 0 M e n o m o n e e F a l l s W i s c o n s i n 5 3 0 5 2 0 4 5 0 U S A PHONE 262 251 3800 FAX 262 251 7067 800 329 8744 U S A ONLY WEBSITE 800 558 8744 U S A CANADA 262 251 190...

Страница 2: ...n properly with a source voltage of between 200 volts and 208 volts With the voltage conversion switch in the 220 240 volt LOWER position the unit will function properly with a source voltage of betwe...

Страница 3: ...e or alkaline chlorinated based commercial detergent or grease solvent at the recommended strength Use a plastic scouring pad or oven cleaner for difficult areas Avoid the use of abrasive cleaning com...

Страница 4: ...ation Information Center at 301 504 6803 Chefs cooks and other specialized food service personnel employ varied methods of cooking Proper holding temperatures for a specific food product must be based...

Страница 5: ...mpty holding cavity DO NOT CALIBRATE WITH ANY FOOD PRODUCT IN THE CABINET The thermostat should be set and should be allowed to stabilize at that setting for a minimum of one hour Following temperatur...

Страница 6: ...Falls Wisconsin 53052 0450 243B 3 88 LOW TEMPERATURE COOKING HOLDING OVENS 500 TH 750 TH II 767 SK 1000 TH I 1000 TH II 1000 TH 1000 TH III A S PN 1115 Bottom of Extra Large Drip Pan is positioned on...

Страница 7: ...er turned ON line voltage when timer and cook thermostat are ON should appear across term 2 and 3 of timer If not replace timer If line voltage does appear across term 2 and 3 of timer it should also...

Страница 8: ...9 INSULATION TUBE MOUNTING SCREWS 6 SC 2059 20 INSULATION Size 25 x 120 635 mm x 3048 mm 1 IN 2381 21 CABLE CONNECTION HARDWARE SHOULDER BUSHING 6 BU 3105 CUP BUSHING 6 BU 3106 HEX NUT 36 NU 2215 RING...

Страница 9: ...Operation and Care Manual 861 8...

Страница 10: ...Operation and Care Manual 861 9...

Страница 11: ...Operation and Care Manual 861 10...

Страница 12: ...notation of this refusal on the receipt 5 If the driver refuses to allow inspection write the following on the delivery receipt Driver refuses to allow inspection of containers for visible damage 6 Te...

Отзывы: