INSTALLATION
Drawer Warmer
▪
Operator’s Manual
▪
M N-46969
▪
Rev 1
▪
5/20
21
Continued from previous page
Regarding international standard drawer warmers:
If the drawer warmer is not equipped with flexible cord and plug, an all-pole
country approved disconnection device which has a contact separation of at least
3mm in all poles must be incorporated in the fixed wiring for disconnection.
When using a cord without a plug, the green/yellow conductor shall be
connected to the terminal which is marked with the ground symbol. If a plug is
used, the socket outlet must be easily accessible. If the power cord needs
replacement, use a similar one obtained from the distributor.
Hard wired drawer warmers:
Hard wired drawer warmers must be equipped with a country certified external
all pole disconnection switch with sufficient contact separation. An oil resistant
cord like H05RN or H07RN or equivalent must be used.
Continued on next page
NOTICE
Where local codes and CE regulatory requirements apply,
appliances must be connected to an electrical circuit that is
protected by an external GFCI outlet.