The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the “
OFF
” position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
230V:
To prevent an electrical shock hazard between
the appliance and other appliances or metal
parts in close vicinity, an equalization-bonding
stud is provided. An equalization bonding lead
must be connected to this stud and the other
appliances / metal parts to provide sufficient
protection against potential difference.
The terminal is marked with the following
symbol.
NOTE:
230V appliances must be connected to an
electrical circuit that is protected by an
external GFCI outlet.
E L E C T R I C A L C O N N E C T I O N
I N S T A L L A T I O N
E L E C T R I C A L - 7 6 7 - S K / I I I
VOLTAGE
PHASE
CYCLE
/
HZ
AMPS
kW
AWG
208-240 (
AGCY
) 1
60
16.0
3.85
NO CORD
at 208
1
60
15.5
3.21
OR PLUG
at 240
1
60
17.8
4.27
230
1
50
16.0
3.68
CEE
7/7
220-230V
PLUG
E L E C T R I C A L - 1 7 6 7 - S K / I I I
VOLTAGE
PHASE
CYCLE
/
HZ
AMPS
kW
AWG
208-240 (
AGCY
) 1
60
32.0
7.70
NO CORD
at 208
1
60
30.9
6.43
OR PLUG
at 240
1
60
35.6
8.55
230
1
50
34.1
7.86
NO CORD
OR PLUG
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
D A N G E R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
E L E C T R I C A L - 2 8 0 0 - S K / I I I
VOLTAGE
PHASE
CYCLE
/
HZ AMPS
kW
AWG
208
1
60
43.1
8.96
CORD
,
NO PLUG
230
1
50
37.1
8.54
NO CORD OR PLUG
208
3
60
27
8.96
NO CORD OR PLUG
380-415 (
AGCY
) 3
50
15.5
9.3
NO CORD OR PLUG
PG
. 10
767-SK/III, 1767-SK/III, 2800-SK/III
INSTALLATION
/
OPERATION
/
SERVICE MANUAL
Содержание 2800-SK/III
Страница 30: ...767 SK III 1767 SK III 2800 SK III INSTALLATION OPERATION SERVICE MANUAL PG 29...
Страница 31: ...PG 30 767 SK III 1767 SK III 2800 SK III INSTALLATION OPERATION SERVICE MANUAL...
Страница 32: ...767 SK III 1767 SK III 2800 SK III INSTALLATION OPERATION SERVICE MANUAL PG 31...
Страница 33: ...PG 32 767 SK III 1767 SK III 2800 SK III INSTALLATION OPERATION SERVICE MANUAL...
Страница 34: ...767 SK III 1767 SK III 2800 SK III INSTALLATION OPERATION SERVICE MANUAL PG 33...
Страница 35: ...PG 34 767 SK III 1767 SK III 2800 SK III INSTALLATION OPERATION SERVICE MANUAL...
Страница 36: ...767 SK III 1767 SK III 2800 SK III INSTALLATION OPERATION SERVICE MANUAL PG 35...
Страница 37: ...PG 36 767 SK III 1767 SK III 2800 SK III INSTALLATION OPERATION SERVICE MANUAL...