O & C M A N U A L # 8 3 1 1 • T H / I I I F A M I L Y
P G . 1 4
S E C T I O N 6
S E R V I C E S E T U P
S E C T I O N 6
Determine Correct Voltage and Unit Setup
1. Verify voltage at outlet or junction box. Make
sure that the voltage is checked between L1 and L2
and from each leg to ground. Each reading should
be within 5% of each other.
2. Verify unit setup by beginning in the
off mode
.
Hold the Cook Key and the Down Arrow Key at
the same time until you hear a brief beep.
If you
hear two brief beeps, the oven is
not
in the off mode.
The oven will display it's setup information.
Option Code
Indicates oven model
programming (see Table B)
Line Voltage
Indicates set voltage
Software Phase
Alph, Beta or Prod
Software Version
Operating software version
example: 2.10
Printer / Lock State
Indicates current status
Left digit:
On-line printing
1 = on
0 = off
Third digit:
On-line Interval
1 = 5"
0 = 1"
Second digit:
Panel Lock
1 = on
0 = off
Right digit:
Preset Lock
1 = on
0 = off
Example: 1101 = on-line printing,
5 minute printing interval, panel
lock off, preset lock on
Option
Model
Max. Temp
Code
Number
°F°=°C
12
500-TH/III - 120V
325=163
13
500-TH/III - 120V
250=121
16
CH-50/III - 120V
325=163
18
500-TH/III
325=163
19
500-TH/III
250=121
22
CH-50/III
325=163
34
750-TH/III
325=163
35
750-TH/III
250=121
38
CH-75/III
325=163
58
767-SK/III
325=163
59
767-SK/III
250=121
66
1000-TH/III
325=163
67
1000-TH/III
250=121
70
CH-100/III
325=163
82
1200-TH/III UPPER
325=163
83
1200-TH/III UPPER
250=121
86
CH-120/III UPPER
325=163
98
1200-TH/III LOWER
325=163
99
1200-TH/III LOWER
250=121
102
CH-120/III LOWER
325=163
Table B
Table C
INSTALLATION REQUIREMENT!
FOR CORRECT OPERATION,
CONTROL MUST BE SET TO
MATCH THE POWER SUPPLY LINE.
Changing the Voltage Setting:
Password 3838
With the oven in the
off mode
, push and hold
the Up and Down Arrow Key at the same time.
After 4 seconds, the display will show a zero
along with 3 dashes. Using the Up Arrow Key,
toggle up until the display shows a 3, then
push the Start Key. Using the Down Arrow
Key, toggle down until the display shows a 8
and push the Start Key. Using the Up Arrow
Key, toggle up until the display shows a 3 and
push the Start Key. Using the Down Arrow
Key, toggle down until the display shows an 8
and push the Start Key. The current set volt-
age will display.
If the setting needs to be changed, use the Up
or Down Arrow Key to select the proper volt-
age as measured at the outlet and then push
the Start Key. The voltage is now set for the
supplied voltage.
The control defaults to 240V on all models except
the 500-TH/III, 125V model. The default for this
unit is 120V.
The oven control must be set to the
line voltage provided by your electric power sup-
plier in order to perform correctly.
As an added
benefit, the unit will operate economically with an
average wattage draw much lower than those stat-
ed on the rating tag as shown below in Table C.
Voltage
Model
Average Power
Setting
Number
Draw (Watts)
200
500-TH/III
1880
750-TH/III
2710
1000-TH/III
2710
1200-TH/III
5420
208
500-TH/III
2030
750-TH/III
2930
1000-TH/III
2930
1200-TH/III
5860
230
500-TH/III
2075
750-TH/III
2860
1000-TH/III
2860
1200-TH/III
5720
240
500-TH/III
2030
750-TH/III
2930
1000-TH/III
2930
1200-TH/III
5860
Содержание 1000-TH/III
Страница 22: ...O C MANUAL 8311 TH III FAMILY PG 20 S E C T I O N 6 S E RV I C E S E C T I O N 6 SERVICE VIEW 1...
Страница 27: ...O C MANUAL 8311 TH III FAMILY PG 25...
Страница 28: ...O C MANUAL 8311 TH III FAMILY PG 26...
Страница 29: ...O C MANUAL 8311 TH III FAMILY PG 27...