Altman Spectra-Strip Series Скачать руководство пользователя страница 3

I N S T A L L A T I O N   A N D   I N S T R U C T I O N   M A N U A L  

 

Spectra-Strip™ LED Series 

Solid State Lighting Fixture 

DESCRIPTION 

The Spectra Strip LED lighting fixture is a portable unit with a flexible power supply cord.  The overall 
construction of the fixture includes corrosion protected aluminum housing.  The fixture is supplied with a 
state of the art microprocessor-controlled solid-state LED light engine incorporating 3-watt Luxeon Rebel 
Red, Green, Blue, and Amber color and/or White 3000°K LEDs, and an on-board power supply. The LED 
substrate is coupled to a highly efficient heat sink and cooling system for prolonged life of the LEDs. The 
fixture can be ceiling mounted to a pipe or floor mounted.  All components and electrical devices are ETL 
Listed or Recognized.  A safety cable is provided for use when 

securing

 the fixture to a pipe. 

 

PACKING LIST 

The Spectra Strip LED lighting fixture is shipped with the following: 

 

 

 

Spectra Strip with 2 Safety Cables. 

 

 

 

PowerCON® Power Supply Cord with Edison power plug. 

 

 

 

1 Safety filter frame for each LED compartment. 

 

 

 

Installation and Instruction Manual. 

 

 

 

WARNING:

  

ALL ELECTRICAL WIRING AND CONNECTIONS SHOULD BE PERFORMED BY A QUALIFIED 
ELECTRICIAN 

 

SETUP AND INSTALLATION 

Unpacking 

Remove the Spectra Strip lighting fixture from its shipping box.  Set the unit  down on a  flat  surface before 
proceeding.  The Spectra Strip is shipped fully assembled and ready for use. 

Lamping and Re-lamping 

 The  Spectra  Strip  lighting  fixture  is  provided  with  an  integral  LED  light  engine.  Under  normal  operating 
conditions, the LED light engine should have a rated life expectancy of over 50,000 hours. There are no user 
serviceable parts inside. The entire LED assembly will need to be changed. 

Содержание Spectra-Strip Series

Страница 1: ...i A L T M A N LI G H TI N G I N C Spectra Strip Series Installation and Instruction Manual ...

Страница 2: ...UCTIONS INSTRUCTIONS DE SÛRETÉ LES INSTRUCTIONS AU SUJET D UN RISQUE D INCENDIE LE CHOC ÉLECTRIQUE OU LA BLESSURE AUX PERSONNES POUR SS CYC 100 AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE LE CHOC ÉLECTRIQUE OU LA BLESSURE AUX PERSONNES SUIVRE CES INSTRUCTIONS DE SÉCURITÉ IMPORTANTES 1 Éteignez débranchez la puissance et permettez au montage de se refroidir avant le nettoyage ou l entretien 2 A...

Страница 3: ...isted or Recognized A safety cable is provided for use when securing the fixture to a pipe PACKING LIST The Spectra Strip LED lighting fixture is shipped with the following Spectra Strip with 2 Safety Cables PowerCON Power Supply Cord with Edison power plug 1 Safety filter frame for each LED compartment Installation and Instruction Manual WARNING ALL ELECTRICAL WIRING AND CONNECTIONS SHOULD BE PER...

Страница 4: ...le Edison plug into a properly grounded receptacle 100 240 VAC connected to a circuit breaker Feed thru PowerCON receptacles gray are provided at the opposite end of each Spectra Strip for powering neighboring Spectra Strips Up to 3 600W Spectra strips maximum should daisy chain power in this fashion All feed thru wiring components are rated at 20 Amps Additional power thru cable assemblies are av...

Страница 5: ...ift the handle to disengage and set the lever to an optimal position Cleaning the fixture Routine cleaning of the Spectra Strip lighting fixture will provide years of prolonged use Use compressed air to blow off any dust and dirt from the lens electronics and heat sink For the lens use a soft lint free cloth dampened with water to clean the lens of dust and dirt Dry off completely with compressed ...

Страница 6: ...ue and Amber for more color combinations and better CRI Compatible with DMX512 and RDM protocols 8 16 bit DMX512 control for smoother dimming On board power supply microprocessor controller and current drivers Feed thru DMX RDM data with a maximum total run of 1000 feet Feed thru PowerCON Outlets Push button addressing Stand Alone Pre programmed Show mode Built in flicker free TV mode Keypad Lock ...

Страница 7: ...I N S T A L L A T I O N A N D I N S T R U C T I O N M A N U A L 7 OPERATION RearPanelControlUnit ...

Страница 8: ...e is NO LONGER listening to the incoming DMX signal and has now become the source of DMX control information for all fixtures coming after it The Master fixture will broadcast the pre built show included in the fixture s software that has been selected by the user All fixtures coming after the Master fixture should be set to Slave to receive the DMX signal originated from the Master fixture This f...

Страница 9: ...lect Preset Select one of the pre programmed presets Note Available presets depends on length of fixture See page 11 for presets Concert Modes CON1 CON6 Concert Mode Concert mode groups individual LED Cells into groups CON1 is all LED cells respond to channels 1 4 RGBA CON6 is each cell responds to channels 1 48 RGBA Theatre Modes THE1 THE6 Theatre Mode Theatre mode groups cells by traditional bor...

Страница 10: ...the show chasing mode for more dynamic effects Default OFF Select DMX start address This is the start address of the first output of the fixture Total amount of addresses per fixture depends on type of fixture and configuration Default Address 1 Note highest value depends on amount of addresses of the fixture Select network resolution Change between 8 and 16 bit resolution Using 16 bit with a 8 bi...

Страница 11: ...I N S T A L L A T I O N A N D I N S T R U C T I O N M A N U A L 11 ...

Страница 12: ... 4 Cell RGBA Cell 1 2 Concert_1 A A Concert_2 A B 4 8 Cell RGBA Cell 1 2 3 4 Concert_1 A A A A Concert_2 A A B B Concert_3 A B C D 6 12 Cell RGBA Cell 1 2 3 4 5 6 7 8 9 10 11 12 Concert_1 A A A A A A A A A A A A Concert_2 A A A A A A B B B B B B Concert_3 A A A A B B B B C C C C Concert_4 A A A B B B C C C D D D Concert_5 A A B B C C D D E E F F Concert_6 A B C D E F G H I J K L Theatre_1 A B C A ...

Отзывы: