SAFETY INSTRUCTIONS 

 
 
INSTRUCTIONS  PERTAINING  TO  A  RISK  OF 
FIRE,  ELECTRICAL  SHOCK,  OR  INJURY  TO 
PERSONS  FOR  SPECTRA  STRIPSERIES  LED 
LIGHTING FIXTURES. 
 

 
WARNING!  -  TO  REDUCE  THE  RISK  OF  FIRE, 
ELECTRIC  SHOCK,  OR  INJURY  TO  PERSONS, 
FOLLOW 

THESE 

IMPORTANT 

SAFETY 

INSTRUCTIONS: 
 
1) 

Turn off, unplug power, and allow fixture to 
cool before cleaning or servicing.  

 
2) 

Ensure that fixture is properly grounded. 

 
3) 

Ensure  that  ventilation  slots  are  not 
obstructed. 

 
4) 

Do not look directly at lighted LEDs. 

 
5) 

Keep away from flammable materials.  

 
6) 

No  user  serviceable  parts  inside.    Replace 
entire LED assembly. 

 
7) 

Do  not  touch  the  LEDs  at  any  time.  Use  a 
soft lint-free cloth to clean lens. Do not use 
solvents to clean. Use cloth  dampened  with 
water.  Allow  to  dry  completely  before 
reenergizing. 

 
8) 

Do  not  operate  the  unit  with  a  missing  or 
damaged lens. 

 
 

----------SAVE THESE INSTRUCTIONS!----------- 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INSTRUCTIONS DE SÛRETÉ 

 
LES  INSTRUCTIONS  AU  SUJET  D'UN 
RISQUE 

D'INCENDIE 

LE 

CHOC 

ÉLECTRIQUE,  O U  LA  B LESSURE  AUX 
PERSONNES POUR SS- CYC- 100. 
  

 
 
AVERTISSEMENT!  -  POUR RÉDUIRE  LE RISQUE 
D'INCENDIE,  LE  CHOC  ÉLECTRIQUE,  OU  LA 
BLESSURE  AUX  PERSONNES,  SUIVRE  CES 
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES: 
 
1)  

Éteignez,  débranchez  la  puissance,  et 
permettez  au  montage  de  se  refroidir  avant 
le nettoyage ou l'entretien.  

 
2) 

Assurez-vous 

que 

le 

montage 

est 

correctement relié à la terre. 

 
3) 

Assurez-vous  que  des  fentes  de  ventillation 
ne sont pas obstruées. 

 
4) 

Ne  regardez  pas  directement  la  LED 
allumée. 

 
5) 

S'éloigner des materiaux inflammables. 

 
6) 

Aucunes  pièces  utiles  d'utilisateur  à 
l'intérieur. Remplacez la LED entière. 

 
7) 

Ne touchez pas la LED à tout moment. 

 

Employez  un  chiffon  non  pelucheux  mou 
pour  nettoyer  l'objectif.  N'employez  pas  les 
dissolvants  pour  nettoyer.peut  employer  le 
tissu  humecté  de  l'eau.laissez  sécher 
complètement avant de reenergizing.  

 
8) 

Ne  pas  faire  fonctionner  l'appareil  avec  un 
diffuseur antérieur ou une lampe. 

 
 

----------GARDER CES INSTRUCTIONS!----------

 

 

Содержание Spectra-Strip Series

Страница 1: ...i A L T M A N LI G H TI N G I N C Spectra Strip Series Installation and Instruction Manual ...

Страница 2: ...UCTIONS INSTRUCTIONS DE SÛRETÉ LES INSTRUCTIONS AU SUJET D UN RISQUE D INCENDIE LE CHOC ÉLECTRIQUE OU LA BLESSURE AUX PERSONNES POUR SS CYC 100 AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE LE CHOC ÉLECTRIQUE OU LA BLESSURE AUX PERSONNES SUIVRE CES INSTRUCTIONS DE SÉCURITÉ IMPORTANTES 1 Éteignez débranchez la puissance et permettez au montage de se refroidir avant le nettoyage ou l entretien 2 A...

Страница 3: ...isted or Recognized A safety cable is provided for use when securing the fixture to a pipe PACKING LIST The Spectra Strip LED lighting fixture is shipped with the following Spectra Strip with 2 Safety Cables PowerCON Power Supply Cord with Edison power plug 1 Safety filter frame for each LED compartment Installation and Instruction Manual WARNING ALL ELECTRICAL WIRING AND CONNECTIONS SHOULD BE PER...

Страница 4: ...le Edison plug into a properly grounded receptacle 100 240 VAC connected to a circuit breaker Feed thru PowerCON receptacles gray are provided at the opposite end of each Spectra Strip for powering neighboring Spectra Strips Up to 3 600W Spectra strips maximum should daisy chain power in this fashion All feed thru wiring components are rated at 20 Amps Additional power thru cable assemblies are av...

Страница 5: ...ift the handle to disengage and set the lever to an optimal position Cleaning the fixture Routine cleaning of the Spectra Strip lighting fixture will provide years of prolonged use Use compressed air to blow off any dust and dirt from the lens electronics and heat sink For the lens use a soft lint free cloth dampened with water to clean the lens of dust and dirt Dry off completely with compressed ...

Страница 6: ...ue and Amber for more color combinations and better CRI Compatible with DMX512 and RDM protocols 8 16 bit DMX512 control for smoother dimming On board power supply microprocessor controller and current drivers Feed thru DMX RDM data with a maximum total run of 1000 feet Feed thru PowerCON Outlets Push button addressing Stand Alone Pre programmed Show mode Built in flicker free TV mode Keypad Lock ...

Страница 7: ...I N S T A L L A T I O N A N D I N S T R U C T I O N M A N U A L 7 OPERATION RearPanelControlUnit ...

Страница 8: ...e is NO LONGER listening to the incoming DMX signal and has now become the source of DMX control information for all fixtures coming after it The Master fixture will broadcast the pre built show included in the fixture s software that has been selected by the user All fixtures coming after the Master fixture should be set to Slave to receive the DMX signal originated from the Master fixture This f...

Страница 9: ...lect Preset Select one of the pre programmed presets Note Available presets depends on length of fixture See page 11 for presets Concert Modes CON1 CON6 Concert Mode Concert mode groups individual LED Cells into groups CON1 is all LED cells respond to channels 1 4 RGBA CON6 is each cell responds to channels 1 48 RGBA Theatre Modes THE1 THE6 Theatre Mode Theatre mode groups cells by traditional bor...

Страница 10: ...the show chasing mode for more dynamic effects Default OFF Select DMX start address This is the start address of the first output of the fixture Total amount of addresses per fixture depends on type of fixture and configuration Default Address 1 Note highest value depends on amount of addresses of the fixture Select network resolution Change between 8 and 16 bit resolution Using 16 bit with a 8 bi...

Страница 11: ...I N S T A L L A T I O N A N D I N S T R U C T I O N M A N U A L 11 ...

Страница 12: ... 4 Cell RGBA Cell 1 2 Concert_1 A A Concert_2 A B 4 8 Cell RGBA Cell 1 2 3 4 Concert_1 A A A A Concert_2 A A B B Concert_3 A B C D 6 12 Cell RGBA Cell 1 2 3 4 5 6 7 8 9 10 11 12 Concert_1 A A A A A A A A A A A A Concert_2 A A A A A A B B B B B B Concert_3 A A A A B B B B C C C C Concert_4 A A A B B B C C C D D D Concert_5 A A B B C C D D E E F F Concert_6 A B C D E F G H I J K L Theatre_1 A B C A ...