background image

INTERFACES

2

2

PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your

VA6822

 Interface. Keep this manual handy for

future reference. These safety instructions are to
ensure the long life of your 

VA6822 

and to prevent

fire and shock hazard. Please read them carefully
and heed all warnings.

1.1 GENERAL

    Unauthorized personnel shall not open the unit

since there are high-voltage components
inside.

   Qualified ALTINEX service personnel, or their

authorized representatives must perform all
service.

1.2. SAFETY GUIDELINES FOR THE RACK-
MOUNTING OF THE VA6822

    Maximum operating ambient temperature is 35

(degrees C).

   Never restrict the airflow through the devices’

fan or vents.

   When installing equipment into a rack,

distribute the units evenly. Otherwise,
hazardous conditions may be created by an
uneven weight distribution.

  Connect the unit to a properly rated supply

circuit.

   Reliable Earthing (Grounding) of Rack-

Mounted Equipment should be maintained.

1.3 INSTALLATION

    For best results, place the 

VA6822

 Interface

on a flat, level surface in a dry area away from
dust and moisture.

   To prevent fire or shock, do not expose this

unit to rain or moisture. Do not place the

VA6822

 Interface in direct sunlight, near

heaters or heat radiating appliances, or near
any liquid. Exposure to direct sunlight, smoke,
or steam can harm internal components.

  Handle the 

VA6822

 Interface carefully.

Dropping or jarring can damage internal
components.

   Do not place heavy objects on top of the

VA6822

. If the 

VA6822

 is to be mounted to a

table or wall, use only ALTINEX-made
mounting accessories like brackets
(

DA1293FC 

or

 DA1294FC

) and cables for

optimum setup.

   To turn off the main power, be sure to remove

the cord from the power outlet. The power
outlet socket should be installed as near to the
equipment as possible, and should be easily
accessible.

    Do not pull the power cord or any cable that is

attached to the 

VA6822

 Interface.

   If the 

VA6822

 Interface is not used for an

extended period, disconnect the power cord
from the power outlet.

1.4 CLEANING

  Unplug the 

VA6822

 power cord before

cleaning. Clean surfaces with a dry cloth.
Never use strong detergents or solvents such
as alcohol or thinner. Do not use a wet cloth or
water to clean the unit.

1.5 FCC / CE NOTICE

   This device complies with part 15 of the FCC

Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.

   This equipment has been tested and found to

comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated
in a commercial environment. This equipment
generates, uses, and can radiate radio
frequency energy and, if not installed and
used in accordance with the instruction
manual, may cause harmful interference to
radio communications. Operation of this
equipment in a residential area is likely to
cause harmful interference in which case the

Содержание System Interface Audio & Equalization VA6822

Страница 1: ...INTERFACES MANUAL PART NUMBER 400 0103 001 PRODUCT REVISION 2 VA6822 SYSTEM INTERFACE WITH AUDIO EQUALIZATION USER S GUIDE...

Страница 2: ...BNC CONNECTORS 5 HORIZONTAL POSITION ADJUSTMENT 5 HORIZONTAL DELAY REMOVAL 6 MOUNTING CAPABILITY 6 POWER REQUIREMENTS 6 BANDWIDTH 6 EQUALIZATION 6 APPLICATION DIAGRAM 8 INSTALLING YOUR INTERFACE 9 OPE...

Страница 3: ...heavy objects on top of the VA6822 If the VA6822 is to be mounted to a table or wall use only ALTINEX made mounting accessories like brackets DA1293FC or DA1294FC and cables for optimum setup To turn...

Страница 4: ...f interfaces Interfaces do not change the scan rate or the resolution of the video signal An interface simply converts a computer video signal to a pre selected analog format The VA6822 is a state of...

Страница 5: ...h remote H position connector Power Power Input 100 240V AC 50 60Hz 0 4A Power Consumption 10 watts max Table 3 VA6822 Electrical Specifications VA6822 DESCRIPTION 4 The VA6822 has two key functions F...

Страница 6: ...VA6822 it can provide RGSB RGBHV or RGBS output signals With these connectors the VA6822 can be connected to compatible data projectors using 3 coax 4 coax or 5 coax cables CONNECTOR MAIN DUAL OUTPUT...

Страница 7: ...WIDTH The typical bandwidth of the VA6822 is 425 MHz The minimum bandwidth is 350 MHz This exceptionally high bandwidth allows passing of the third harmonics of the video signal thus maintaining the h...

Страница 8: ...INTERFACES 7 7 DESCRIPTION OF VA6822 4...

Страница 9: ...INTERFACES 8 8 APPLICATION DIAGRAM 5...

Страница 10: ...V signals Step 6 Connect the main audio output from the VA6822 through the provided 5 position terminal block to the input of a sound system amplifier Step 7 Make sure that the dip switches are set as...

Страница 11: ...in the OFF position By putting it in the ON position the duration of Vertical SYNC of the signal is reduced to 10ms This allows stability of the signal on a long run cable It is not recommended to use...

Страница 12: ...S8155CA MS8165CA VGA local monitor output cable MS8126CA MS8156CA MS8166CA VGA input cable MAC MS8121CA MS8151CA MS8161CA MAC local monitor output cable MS8122CA MS8152CA MS8162CA MAC input cable SUN...

Страница 13: ...d to the Interface It should turn GREEN when both power and a valid input signal is applied If the power LED is absent when the unit is turned ON return the VA6822 to the factory for repair 2 Make sur...

Страница 14: ...o ALTINEX that you receive the products that you have ordered and that this product meets your expectations In the unlikely event that an ALTINEX product needs to be returned please follow the policy...

Отзывы: