background image

INTERFACES

9

9

INSTALLING YOUR INTERFACE

6

Step 1.

Please attach the 

VA6822

 Interface on

the rack using the provided rack mount
hardware or on/under furniture using the
optional 

TM

 Series ALTINEX brackets.

Step 2.

Connect one end of the input cable to the
video output connector of the source
computer and the other end to the
computer input port of the 

VA6822

.

Step 3.

Connect

 

an audio input cable’s 3.5mm

plug to the audio output of a source
computer and the other end to the audio
input connector of the 

VA6822.

 If needed,

use a similar cable to connect the audio
output of the 

VA6822 

to a speaker or

audio equipment.

Step 4.

Connect the local monitor output
connector of the 

VA6822

 to a local

monitor or display using the appropriate
ALTINEX Local Monitor cables. It is not
necessary to terminate this output with a
termination plug if a local monitor is not
being used.

Step 5.

Connect one end of a coaxial cable to the
main output of the 

VA6822 

and the other

end to the RGBHV/RGBS input on the
projector or monitor. Usually either a 4
BNC or 5 BNC coaxial cable
is used, depending on whether the display
devices require composite sync (RGBS)
or separate horizontal and vertical sync
(RGBHV) signals.

Step 6.

Connect the main audio output from the

VA6822 

through the provided 5-position

terminal block to the input of a sound
system amplifier.

Step 7.

Make sure that the dip- switches are set
as described in section 7.

Step 8.

Using the provided power cable for your
country of usage, connect the power input
IEC connector to the AC wall outlet. The
power supply used in the 

VA6822 

is

universal so it can accept from 100 VAC

to 240 VAC 50/60Hz. It is not necessary
to change any voltage selection settings
on the 

VA6822

.

 

The LED on the front and

back panel of the 

VA6822 

will light

GREEN if the appropriate input signal is
present and will remain RED if a valid
input is not detected.

Step 9.

It is recommended that you move the

VA6822

’s horizontal position dial to the far

right facing the front until it clicks. This will
disable the movement of the horizontal
position of the image. The horizontal
position of the image should first be
adjusted using the control provided by the
monitor or projector. If further adjustments
are still required, then image can be
adjusted using the horizontal position
control dial located on the front of the

VA6822

.

Step 10.

Adjust the equalization channels for the
Red, Green, and Blue channels to get the
best possible image on the display. It is
recommended to increase equalization on
all three channels simultaneously until the
picture is perfect.

Содержание System Interface Audio & Equalization VA6822

Страница 1: ...INTERFACES MANUAL PART NUMBER 400 0103 001 PRODUCT REVISION 2 VA6822 SYSTEM INTERFACE WITH AUDIO EQUALIZATION USER S GUIDE...

Страница 2: ...BNC CONNECTORS 5 HORIZONTAL POSITION ADJUSTMENT 5 HORIZONTAL DELAY REMOVAL 6 MOUNTING CAPABILITY 6 POWER REQUIREMENTS 6 BANDWIDTH 6 EQUALIZATION 6 APPLICATION DIAGRAM 8 INSTALLING YOUR INTERFACE 9 OPE...

Страница 3: ...heavy objects on top of the VA6822 If the VA6822 is to be mounted to a table or wall use only ALTINEX made mounting accessories like brackets DA1293FC or DA1294FC and cables for optimum setup To turn...

Страница 4: ...f interfaces Interfaces do not change the scan rate or the resolution of the video signal An interface simply converts a computer video signal to a pre selected analog format The VA6822 is a state of...

Страница 5: ...h remote H position connector Power Power Input 100 240V AC 50 60Hz 0 4A Power Consumption 10 watts max Table 3 VA6822 Electrical Specifications VA6822 DESCRIPTION 4 The VA6822 has two key functions F...

Страница 6: ...VA6822 it can provide RGSB RGBHV or RGBS output signals With these connectors the VA6822 can be connected to compatible data projectors using 3 coax 4 coax or 5 coax cables CONNECTOR MAIN DUAL OUTPUT...

Страница 7: ...WIDTH The typical bandwidth of the VA6822 is 425 MHz The minimum bandwidth is 350 MHz This exceptionally high bandwidth allows passing of the third harmonics of the video signal thus maintaining the h...

Страница 8: ...INTERFACES 7 7 DESCRIPTION OF VA6822 4...

Страница 9: ...INTERFACES 8 8 APPLICATION DIAGRAM 5...

Страница 10: ...V signals Step 6 Connect the main audio output from the VA6822 through the provided 5 position terminal block to the input of a sound system amplifier Step 7 Make sure that the dip switches are set as...

Страница 11: ...in the OFF position By putting it in the ON position the duration of Vertical SYNC of the signal is reduced to 10ms This allows stability of the signal on a long run cable It is not recommended to use...

Страница 12: ...S8155CA MS8165CA VGA local monitor output cable MS8126CA MS8156CA MS8166CA VGA input cable MAC MS8121CA MS8151CA MS8161CA MAC local monitor output cable MS8122CA MS8152CA MS8162CA MAC input cable SUN...

Страница 13: ...d to the Interface It should turn GREEN when both power and a valid input signal is applied If the power LED is absent when the unit is turned ON return the VA6822 to the factory for repair 2 Make sur...

Страница 14: ...o ALTINEX that you receive the products that you have ordered and that this product meets your expectations In the unlikely event that an ALTINEX product needs to be returned please follow the policy...