background image

SWITCHERS

14

ALTINEX POLICY

11

11.1 LIMITED WARRANTY

ALTINEX warrants that its products and cables are
free from defects in materials under normal use
and service. This warranty is limited to repairing at
company’s factory any part or parts of the product,
which upon company’s examination shall disclose
to be, thus defective. Products considered
defective should be returned to company with
transportation charges pre-paid within 2 years (90
days for cables) from date of shipment to the
purchaser. The warranty is expressly instead of all
other warranties expressed or implied. ALTINEX
neither assumes nor authorizes any other person to
assume for it any other liability in connection with
the sale of the products. This warranty shall not
apply to any product that shall have been repaired
or altered outside of company’s factory in any way
so as, in its judgment, to affect its stability or
reliability, or that has been subject to misuse,
negligence or accident.

11.2 RETURN POLICY

It is very important to ALTINEX that you receive the
products that you have ordered and that this
product fulfills your need. In the unlikely event, that
an ALTINEX product needs to be returned please
follow the policies below:

Altinex will accept product returns for a period of 30
days from authorized ALTINEX dealers. Products
should be returned in an unopened package.

If a product has been opened, the restocking fees
will apply. For the restocking fee amount, please
contact an ALTINEX Sales Representative.

If the product is in your possession for more than
30 days, the restocking fees will apply.

ALTINEX will not accept any returns on cables or
custom products.

If your product is in warranty and needs service,
contact the ALTINEX Sales Department for an
RMA (Return Material Authorization). Products
returned without an RMA number may experience
a delay in service.

If your product is out of warranty and needs
service, contact the ALTINEX Sales Department for
an RMA (Return Material Authorization). Products
returned without an RMA number may experience
a delay in service. The service charges will be
quoted to you before the actual repairs are done.

11.3 CONTACT INFORMATION

ALTINEX, Inc.

Tel:

714-990-2300

Toll Free:

1-800-ALTINEX

Fax: 

714-990-3303

E-mail:

[email protected]

Web:

www.altinex.com

Содержание MX2436RM

Страница 1: ...SWITCHERS MANUAL PART NUMBER 400 0129 001 PRODUCT REVISION 0 MX2436RM 6 IN 1 OUT COMPOSITE VIDEO AUDIO SWITCHER USER S GUIDE...

Страница 2: ...DE 5 AUDIO BREAK AWAY MODE 5 EQUALIZATION MODE 5 AUTO SWITCH MODE 5 AUTO ROTATION MODE 5 AUDIO VOLUME CONTROL 5 VERTICAL INTERVAL SWITCHING 5 BEEP ON OFF MODE 5 RESET MODE 5 FACTORY RESET MODE 5 APPLI...

Страница 3: ...of the MX2436RM If the MX2436RM is to be mounted to a table or wall use only ALTINEX made mounting accessories such as rack mount shelf DA1298RM or rack mount ears DA1292FC and cables for optimum setu...

Страница 4: ...units can be rack mounted side by side TECHNICAL SPECIFICATION 3 FEATURES DESCRIPTION Audio Video GENERAL Inputs 6 8 Input Connector Six 5 conductor terminal blocks Eight BNC Female Outputs 1 1 Outpu...

Страница 5: ...SWITCHERS 4 DESCRIPTION OF MX2436RM 4...

Страница 6: ...puts connected to the video output will be selected alternately Audio inputs will simultaneously connect to the audio output along with video inputs if the user did not previously select AUDIO BREAK A...

Страница 7: ...SWITCHERS 6 APPLICATION DIAGRAM 5...

Страница 8: ...pressed and released a beeper will sound once If a button is pressed and held a beeper will sound several times 2 Default video and audio inputs are selected simultaneously by pressing and releasing...

Страница 9: ...e primary communication standard used by control systems and computers In fact the MX2436RM offers more features using RS 232 than are currently available from the front panel of the unit The MX2436RM...

Страница 10: ...fter processing a valid command an OK string will be returned if requested by the feedback command 7 2 2 PROGRAMMING COMMANDS NOTE These programming commands are used for programming the switcher they...

Страница 11: ...ated by the factory default setting Note that previously stored settings will be lost Example Sending the 8RF command resets the Switcher module with ID number eight to the factory settings 4 RO Opera...

Страница 12: ...er eight In addition by default the switcher still has ID number zero 9 CA n1 n2 Audio Gain Control Save Settings Switch number default is 0 no from 1 to 9 n1 Audio input number no from 0 to 6 n2 Audi...

Страница 13: ...DA1298RM Rack mount shelf for two units side by side DA1292RM Rack mount ears for single unit HIGH RESOLUTION 5 BNC to 5 BNC COAXIAL CABLE CB4200MR Bulk Cable 5 coaxes 500ft minimum CB4203MR 3 feet 5...

Страница 14: ...ignal formats 5 Can the MX2436RM Switcher be used outside of the United States Yes the MX2436RM uses a universal internal power supply enabling it to be used throughout the world Please make sure to u...

Страница 15: ...ducts that you have ordered and that this product fulfills your need In the unlikely event that an ALTINEX product needs to be returned please follow the policies below Altinex will accept product ret...

Отзывы: