6. [#Bn] - Beep ON/OFF
#
= Switcher module ID number (default is 0)
n
= ON/OFF switch
n
= 1 (Turns switcher Beep ON)
n
= 0 (Turns switcher Beep OFF)
This command activates or deactivates the
beeping sound when a key is pressed on the
switcher module.
Example:
Sending the command
[8B1]
set the beeper ON
in the connected Switcher module with ID
number eight.
7. [OASn] - Auto Switch
n
= ON/OFF switch
n
= 1 (Turns auto switcher ON)
n
= 0 (Turns auto switcher OFF)
The
[OASn]
command sets the switcher
module to the ON position to auto detect the
incoming audio or video signals or OFF to
operate it manually or with a PC software.
Example:
Sending the
[OAS1]
command will set the auto
switch feature to the ON position, which will
automatically detect the incoming video signal.
8. [0I#] - Change Identification Number
0
= Zero
#
= New Switcher module ID number (no.
from 1 to 9).
This command sets a unique ID number to each
MX2436RM
Switcher
module. A total of 9 unit
ID’s can be assigned.
Example:
Sending the command
[0I8]
will reset the active
Switcher module with the new ID number eight.
In addition, by default the switcher still has ID
number zero.
9. [#CA n1 n2 ] - Audio Gain Control Save
Settings
#
= Switch number (default is 0; no. from 1
to 9).
n1
= Audio input number (no. from 0 to 6).
n2
= Audio Gain (Hexadecimal no. from 1 to
F).
The
[#CA n1 n2 ]
command will save the
volume settings for a specified audio input.
Example:
After the
[8CA6F]
command has been
executed, switcher module
8
and Audio Input
number
6
will have a maximum volume of
F
(0
= OFF, default is 8 or normal volume).
10. [#CA n1 n2 ] – Video Equalization Save
Settings
#
= Switch number (default is 0; no. from
1 to 9).
n1
= Video input number (no. from 0 to 6)
n2
= Video equalization. (Hexadecimal no.
from 1 to F).
This command saves the settings of equalized
video signals to compensate for cable lengths
from the video source to the switcher.
Example:
When sending the
[8CA58]
command, Switcher
module
8
and Video Input number
5
will have a
medium equalization range of
8
(0 = OFF).
11. [#VR] - Firmware Version
This command displays the firmware revision
number that is installed into the microprocessor.
#
= Switch number (default is 0; no. from 1 to
9).
Example:
When sending the
[8VR]
command the system
will return the version number 8R1.0.
When
sending the
[0VR]
command the system will
return the version number 8R1.0.