background image

SWITCHERS

12

respond?

6

How do I
control
several
switchers
with one
RS-232
card in a
control
system?

You can control multiple
switchers with one card at this
time. The unit does have ID
codes and can be
differentiated by the control
system. Call Altinex if this
requirement is important for
your system.

7

Can I use
contact
closure to
control the
switcher?

A special cable that plugs into
the RS-232 port and converts
contact closure into analog
control is available. This is

RC5204CC

 cable is made by

Altinex on request.

8

Can this
switcher be
used
outside of
the United
States?

Yes, the 

MX2206RM

 uses a

universal internal power
supply, enabling it to be used
throughout the world. Please
make sure to have the voltage
setting in the correct position
and please make sure to use
the proper adapter cable for
the country it will be used.
Adapter cables for several
countries are available through
Altinex.

TROUBLESHOOTING GUIDE

10

 Please make sure, that input signal formats are

same for input (source) and output (display).

 Please make sure that input signal amplitude

level is as follows:

1. RED, GREEN, & BLUE are less than 10 V.

2. SYNC is less than 1.0 V and more than 0.3

V.

 Please use the appropriate input voltage

110 VAC or 220 VAC.

 Please make sure that the proper quality of

cables is used. We recommended Altinex made
cables for the best results.

 If the problem shows up after continuous usage

at higher voltage, higher temperature, higher
humidity or at other extreme environmental
conditions, please correct that.

 Please reset the unit by pressing the RESET

key for more than 2 seconds, if problem exists
with the switcher.

 Make sure that all channels (inputs) are not

OFF (i.e. RED LED is not ON next to STAND
BY key).

 If you are using any control software or

hardware to control 

MX2206RM

, then first

verify operation of the unit using MX Control
software available from Altinex web-site:

www.altinex.com

. Make sure that cable is made

according to manual, where RX pin of the

MX2206RM

 is connected to TX pin of the

computer.

 If you are controlling the unit by RS-232

command, make sure there is minimum delay
of 100 milliseconds before sending the next
command.

 If you have multiple 

MX2206RM

 units

connected in Master-Slave mode or Loop-
Control mode, please make sure to have
connection of RS-232 port done according to
manual.

Содержание MX2206RM

Страница 1: ...SWITCHERS MANUAL PART NUMBER 400 0065 003 PRODUCT REVISION 1 MX2206RM 6 IN 1 OUT RGBS AUTO SWITCHER USER S GUIDE...

Страница 2: ...n the ranks of our many satisfied customers throughout the world This manual covers MX2206RM 6 in 1 out RGBS Auto Switcher TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RACK MOUNT SAF...

Страница 3: ...accessories like rack mount shelf DA1298RM or rack mount ears DA1299RM and cables for optimum setup To turn off the main power be sure to remove the cord from the power outlet The power outlet socket...

Страница 4: ...nc Delay times may be selected 0 delay 0 5 second delay 1 5 second delay and 2 0 second delay pre set while powering on the unit The MX2206RM offers a 9 pin control port which provides a means of inte...

Страница 5: ...ibility Typical Video Bandwidth 200 MHz Horizontal 15 200 kHz Vertical 20 190 Hz Cross talk 48dB 10 MHz Coupling DC Power External Power Adapter 90 140V 200 240V Power Consumption 20 watts max Table 3...

Страница 6: ...2 seconds When in Auto Switch mode the rear panel LED lights will scan for an active signal until one is found Auto switching is only available when switching RGBS format signals 4 5 STAND BY ALL CHAN...

Страница 7: ...the same channel The simplicity of this approach is that only 2 wires one to pin 9 and one to ground are required to connect and control all of the switchers The selection of channels can also be acco...

Страница 8: ...ss to a variety of control capabilities PIN No PIN Designation 1 No connection 2 RS 232 Transmit 3 RS 232 Receive 4 No connection 5 Ground 6 Multiple Switcher Loop Control 7 Analog Switch Voltage Inpu...

Страница 9: ...stem being used is not setup to wait for the OK string it is important to include a 100 milliseconds delay between each command The MX2206RM Switcher is also designed to send feedback commands from th...

Страница 10: ...e using pin 9 and pin 7 MX2206RM 9 pin D Master PIN No MX2206RM 9 pin D Slave PIN No 9 7 5 5 Master Slave Analog Switch Voltage Connection With this configuration the Master unit has ultimate control...

Страница 11: ...specifically the output of one switcher is connected to INPUT 6 of the next switcher Once loop control is enabled these switchers will automatically switch video signal to the output of the second swi...

Страница 12: ...CABLES PC5301US Power cable for US PC5302US Power cable for U K PC5303US Power cable for Australia PC5304US Power cable for Germany FREQUENTLY ASKED QUESTIONS 9 No Question Answer 1 Why do the LED li...

Страница 13: ...tude level is as follows 1 RED GREEN BLUE are less than 10 V 2 SYNC is less than 1 0 V and more than 0 3 V Please use the appropriate input voltage 110 VAC or 220 VAC Please make sure that the proper...

Страница 14: ...ts that you have ordered and that this product fulfills your need In the unlikely event that an Altinex product needs to be returned please follow the policies below Altinex will accept product return...

Отзывы: