background image

SWITCHERS

10

The following voltages apply for selecting the
required channel:

Input number

min. (V)

nom. (V)

max. (V)

1

0.35

0.55

0.75

2

1.07

1.27

1.47

3

1.80

2.00

2.20

4

2.52

2.72

2.92

5

3.25

3.45

3.65

6

3.97

4.17

4.37

These voltage levels can be set using analog
outputs from different control systems or spare
dimmer control outputs.

7.5 MANUAL LOOP CONTROL

Loop control is used when multiple units of the

MX2206RM

 are connected together to form a

single switcher. When the input channel button is
pressed the loop control pin is internally grounded
and the

 MX2206RM

 Switcher selects INPUT 4 as

the default input.

In this configuration the loop control pin 6 on the 9
pin D connector is connected to the same pin on all
switchers.

MX2206RM

 LOOP

MX2206RM

 LOOP

6

6

5

5

MX2206RM

 9-pin “D” Loop

The loop control pin has an internal 100k resistor to
+5volts. This limits the number of switchers that
can be looped to a maximum of 10 switchers that
can be daisy chained together using this method.

More specifically, the output of one switcher is
connected to INPUT 6 of the next switcher. Once
loop control is enabled these switchers will

automatically switch video signal to the output of
the second switcher through INPUT 6. Keep in
mind that you are always going to have one less
input then total number of inputs available on all
switchers. The figure above is for an 11-in 1-out
Switcher.

7.6 LOOP CONTROL WITH RS-232 COMMAND

When multiple 

MX2206RM

 units are connected

together to get a single switcher and RS-232
commands are used to control these units, please
connect units according to following diagram.

If you want to make 11 by 1 switcher using two 6
by 1 switchers, the following commands need to be
used to control these switchers:

Input 1 through Input 6

[OUT01]

Input 7 through Input 11

[OUT02]

This will setup each switcher as a different output
number. To control the switchers use following
commands (connect transmit line from control
system to receive line on both switchers):

[I01O01]

Select input number 1

[I02O01]

Select input number 2

[I03O01]

Select input number 3

[I04O01]

Select input number 4

[I05O01]

Select input number 5

[I06O01]

Select input number 6

[I01O02]

Select input number 7

Содержание MX2206RM

Страница 1: ...SWITCHERS MANUAL PART NUMBER 400 0065 003 PRODUCT REVISION 1 MX2206RM 6 IN 1 OUT RGBS AUTO SWITCHER USER S GUIDE...

Страница 2: ...n the ranks of our many satisfied customers throughout the world This manual covers MX2206RM 6 in 1 out RGBS Auto Switcher TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RACK MOUNT SAF...

Страница 3: ...accessories like rack mount shelf DA1298RM or rack mount ears DA1299RM and cables for optimum setup To turn off the main power be sure to remove the cord from the power outlet The power outlet socket...

Страница 4: ...nc Delay times may be selected 0 delay 0 5 second delay 1 5 second delay and 2 0 second delay pre set while powering on the unit The MX2206RM offers a 9 pin control port which provides a means of inte...

Страница 5: ...ibility Typical Video Bandwidth 200 MHz Horizontal 15 200 kHz Vertical 20 190 Hz Cross talk 48dB 10 MHz Coupling DC Power External Power Adapter 90 140V 200 240V Power Consumption 20 watts max Table 3...

Страница 6: ...2 seconds When in Auto Switch mode the rear panel LED lights will scan for an active signal until one is found Auto switching is only available when switching RGBS format signals 4 5 STAND BY ALL CHAN...

Страница 7: ...the same channel The simplicity of this approach is that only 2 wires one to pin 9 and one to ground are required to connect and control all of the switchers The selection of channels can also be acco...

Страница 8: ...ss to a variety of control capabilities PIN No PIN Designation 1 No connection 2 RS 232 Transmit 3 RS 232 Receive 4 No connection 5 Ground 6 Multiple Switcher Loop Control 7 Analog Switch Voltage Inpu...

Страница 9: ...stem being used is not setup to wait for the OK string it is important to include a 100 milliseconds delay between each command The MX2206RM Switcher is also designed to send feedback commands from th...

Страница 10: ...e using pin 9 and pin 7 MX2206RM 9 pin D Master PIN No MX2206RM 9 pin D Slave PIN No 9 7 5 5 Master Slave Analog Switch Voltage Connection With this configuration the Master unit has ultimate control...

Страница 11: ...specifically the output of one switcher is connected to INPUT 6 of the next switcher Once loop control is enabled these switchers will automatically switch video signal to the output of the second swi...

Страница 12: ...CABLES PC5301US Power cable for US PC5302US Power cable for U K PC5303US Power cable for Australia PC5304US Power cable for Germany FREQUENTLY ASKED QUESTIONS 9 No Question Answer 1 Why do the LED li...

Страница 13: ...tude level is as follows 1 RED GREEN BLUE are less than 10 V 2 SYNC is less than 1 0 V and more than 0 3 V Please use the appropriate input voltage 110 VAC or 220 VAC Please make sure that the proper...

Страница 14: ...ts that you have ordered and that this product fulfills your need In the unlikely event that an Altinex product needs to be returned please follow the policies below Altinex will accept product return...

Отзывы: