MULTITASKER™
18
8.4 REMOTE IMAGE QUALITY IS POOR
Cause 1:
The source has a problem.
Solution:
Check the image on the local
monitor and verify the quality is
good. If the local image is good, see
Cause 2.
Cause 2:
Video equalization required.
Solution:
Adjust the VIDEO EQUALIZATION
on the
MT103-122
. Long cable runs
may require adjustment on both the
MT103-122
and the receiver. If the
image is still not correct, call
ALTINEX at (714) 990-2300.
8.5 NO SOUND
Cause 1:
The source has a problem.
Solution:
Check the source and make sure
that there is a signal present and all
source connections are correct. If
the source is working and there is
still no sound, see Cause 2.
Cause 2:
The volume is too low.
Solution:
Increase the AUDIO GAIN toward
maximum. If there is still no sound
present, see Cause 3.
Cause 3:
Cable connections are incorrect.
Solution:
Make sure that cables are properly
connected. Also, make sure that the
continuity and wiring are good. If
there is still no sound, see Cause 4.
Cause 4:
The receiving device has a
problem.
Solution:
Make sure the receiving device has
power and is turned ON. If there is
still no sound, please call Altinex at
(714) 990-2300.
ALTINEX POLICY
9
9.1 LIMITED WARRANTY/RETURN POLICY
Please see the Altinex website at
www.altinex.com for details on warranty and
return policy.
9.2 CONTACT INFORMATION
ALTINEX, INC
592 Apollo street
Brea, CA 92821 USA
TEL:
714 990-2300
TOLL FREE:
1-800-ALTINEX
WEB:
www.altinex.com
E-MAIL: