background image

Protran® PR3850 User Manual

3

5

8

ALTHEN GmbH Mess- und Sensortechnik

Dieselstrasse 2 | 65779 Kelkheim | Germany

Phone: +49 (0)6195 7 00 60 | Fax: +49 (0)6195 70 06 66

Email: [email protected] | www.althensensors.com

Safety & 

Maintenance

General 

Information

 Product 

Instructions

ATEX Product 

Instructions

Dimensions

15

Version &

Disclaimer

11

13

Vers. 22/6/Eng

Protran® PR3850

 

User Manual

Содержание Protran PR3850

Страница 1: ...e 2 65779 Kelkheim Germany Phone 49 0 6195 7 00 60 Fax 49 0 6195 70 06 66 Email info althen de www althensensors com Safety Maintenance General Information Product Instructions ATEX Product Instructions Dimensions 15 Version Disclaimer 11 13 Vers 22 6 Eng Protran PR3850 User Manual ...

Страница 2: ... Intended Use 4 Safety 5 Maintenance and Care 6 Troubleshooting 7 Recycling 7 Product Instructions 8 Connections and Tightening Torques 9 ATEX Product Instructions 11 Technical Specifications 14 Version Information 15 Disclaimer 15 Contents Page Dimensions 13 Protran PR3850 User Manual ...

Страница 3: ...ical specifications For options not listed please contact info althen de for support These operating instructions describe the safe and efficient handling and operation of the pressure transmitter or transducer and must be carefully read and understood prior to use Compliance with the specifications regarding safety and operation contained in these instructions is a prerequisite for safe operation...

Страница 4: ... account the environmental conditions such as temperature humidity and atmospheric pressure etc Should be handled by qualified technical personnel only Limitation of Liability The manufacturer is not liable for damage resulting from non observance of these operating instructions Safety symbols The explanations of the symbols used in these operating instructions are listed below Type and Source of ...

Страница 5: ...ARD HAZARD NOTICE Handling with Hydrogen NOT for use with Hydrogen Selection of personnel Only authorised and qualified personnel who have had experience and knowledge of the country specific regulations as well as the applicable standards and directives may be used for installation and operation Installation and commissioning must be carried out in accordance with these operating instructions The...

Страница 6: ...cer for damage when unpacking If the pressure transmitter is damaged contact the manufacturer or your local dealer immediately WARNING Improper storage Improper storage of the pressure transducer may result in damage or malfunction of the product WARNING Ambient conditions during storage Temperature 5 C to 40 C Store in dry conditions System may be under pressure Loose parts and escaping media may...

Страница 7: ...Adhere to temperature range Replace transmitter Clean pressure inlet hole Signal span outside of specification Output signal fluctuates noises EMC interference sources outside the specification Operating outside of temperature Measuring cell damaged e g by overpressure Pressure connection hole blocked Zero point signal outside of specification Measuring cell damage Operating outside of temperature...

Страница 8: ...ogy Ensure electrical connector and cable gland are securely fitted and sealed MAINTENANCE Recalibration interval depends on own industry guidelines Do not insert pointed or hard objects in to the pressure port Repairs must be performed by manufacturer only REMOVAL END OF LIFE Ensure system is depressurised before removal Remaining media in pressure port may be hazardous Ensure system is not press...

Страница 9: ...nnections and Tightening Torques PR3850 SERIES Process Connection Sealing Method Counter Part Weld Socket Part No 8016 Part No Z0093 O Ring Sensitive Membrane handle with care 9 Protran PR3850 User Manual ...

Страница 10: ...rication coating and surface treatment If in doubt the manufacturer is to be consulted It is recommended that the PR3850 is used in conjunction with weld socket part No 8016 for best results Alternatively customer may machine an appropriate mating connection in their equipment to replicate the dimensions detailed in part 8016 detailed diagrams available on request Materials for mating part should ...

Страница 11: ...e permanently fixed to the housing WARNING POTENTIAL ELECTROSTATIC CHARGING HAZARD DUE TO PROPOGATING BRUSH DISCHARGE SEE INSTRUCTIONS ATEX Product Instructions Specified to hazardous area installations Reference European ATEX Directive 2014 34 EU Annex II 1 0 6 The following instructions apply to equipment covered by certificate numbers TRAC12ATEX0060X V2 IECEXTRC12 0025X issue 01 The wording and...

Страница 12: ...Damp Cloth the wording of the label shall include the words Warning Danger of propagating brush discharge followed by the warning symbol ISO3864 No B 3 1 black exclamation mark in black triangle meaning Caution refer to accompanying documents The manufacturer s instructions shall include details of the ignition hazard caused by propagating brush discharges and the precautions to be taken to avoid ...

Страница 13: ...ase Notes 1 Item is shown for pictorial purpose only to define citical dimensions 2 Construction shall be in accordance with specification information 3 Label will show product name range and output signal Pin No 1 2 3 2 wire supply 4 20mA sig N C to case ELECTRICAL CONNECTION Vdc 13 Protran PR3850 User Manual ...

Страница 14: ...mbient and Media 20 C to 85 C 4 F to 185 F 1 0 FS at room temperature 5 FS approx adjustment with easy access trimming potentiometers on amplified versions only Overpressure Safety PR3850 other options available Mating socket EN175301 803 Form A ex DIN43650 rated IP65 with PG9 cable entry Net Weight Kg 0 3 Kg Electrical Connection Response time 10 90 10 mS Wetted Parts SAE 316L stainless steel Pre...

Страница 15: ...risk Althen will not be liable for any losses and or damages incurred from inproper use of equipment Althen operated a policy of continuous product development We reserve the right to change specification without prior notice All products manufactured by Althen are calibrated using precision calibration equipment traceable to national measurement standards Information provided within this manual i...

Отзывы: