DXR Drainback
Page 19
ELECTRICAL INSTALLATION
A qualified electrician or contractor is required to install all electrical components and wiring. Connections should
be made in accordance with local electrical codes. A 115-120VAC duplex receptacle is required, adjacent to the
water heater, to supply power to the differential controller which provides electrical service to the pumps. The
installer should consult the manufacturer’s documentation for specific installation instructions when a water heater
time switch is to be installed.
EAGLESUN DIFFERENTIAL TEMPERATURE CONTROLLER
The EagleSun Delta-T Control / Energy Meter, is designed for use on a solar thermal water heating system. It will
monitor collector and storage water temperature sensors and operate their respective water pump(s) in order to
maintain desired differential temperature between them; integral variable speed drive on the collector pump and turn
on/off on the storage pump; read from the flow sensor and auxiliary (2) temperature sensors to calculate the BTU’s;
transmit data to the PC via RS-232 for the purpose of data logging and long term diagnostics; power and transmit
data to the remote display panel.
See instructions provided with controller in box for proper installation.
It is recommended that the controller high temperature limit be
set to 140°F and the tank backup element adjusted to 120°F.
Inputs
Line voltage; Power cord
115Vac (L, N, G), 15Amps
Collector sensor, COL
10k Thermistor, 5Vdc circuit
Storage sensor, STO
10k Thermistor, 5Vdc circuit
Auxiliary sensor 1, AUX1
10k Thermistor, 5Vdc circuit
Auxiliary sensor 2, AUX2
10k Thermistor, 5Vdc circuit
Flow sensor; FLO, FS, GND, 5V
5Vdc circuits
Outputs
Variable speed pump, VAR SPEED
Phase controlled line voltage, Triac: 4Amps max
Fixed speed pump, FIXED SPEED
Line voltage, Relay contacts: 20A (or 2HP motor)@240VAC, NO
Communication:
COM
5Vdc
power,
TX (RS-232) at 10Vdc, RJ45 jack