Altera Corporation
2–25
January 2005
Stratix GX Transceiver User Guide
Stratix GX Analog Description
Figure 2–17. MegaWizard Plug-In Manager - ALTGXB (Page 5 of 7) - Receiver (3)
Notes to
(1)
Optional input signal that forces the CRU to lock to the reference clock. This disables the auto switch- over mode
that switches the CRU to lock-to-data mode. If both
rx_locktorefclk
and
rx_locktodata
are asserted, then
rx_locktodata
takes precedence.
(2)
Optional input signal that forces the CRU to lock to the incoming data. If both
rx_locktorefclk
and
rx_locktodata
are asserted,
rx_locktodata
takes precedence.
(3)
Optional output signal that indicates when the CRU is locked to the incoming data stream. The lock indication is
based on the following conditions:
a. The CRU PLL is within the prescribed PPM frequency threshold setting (125 PPM, 250 PPM, 500 PPM, 1,000 PPM)
of the CRU reference clock.
b. The reference clock and CRU PLL output are phase matched (~ phases are within 0.08 UI).
Содержание Stratix GX
Страница 18: ...1 10 Altera Corporation Stratix GX Transceiver User Guide January 2005 Modes of Operation ...
Страница 46: ...2 28 Altera Corporation Stratix GX Transceiver User Guide January 2005 MegaWizard Analog Features ...
Страница 154: ...5 42 Altera Corporation Stratix GX Transceiver User Guide January 2005 XAUI Mode MegaWizard Plug In Manager ...
Страница 200: ...6 46 Altera Corporation Stratix GX Transceiver User Guide January 2005 Design Example ...
Страница 296: ...A 12 Altera Corporation Stratix GX Transceiver User Guide January 2005 8B 10B Code ...
Страница 318: ...C 8 Altera Corporation Stratix GX Transceiver User Guide January 2005 Known Issues ...