Pin

Name

I/O

Description

Logic

1

POWER STAGE ON

In

Enables power section

High level enables

2

HIGH VOLTAGE ON

In

Enables high voltage section

High level enables

3

MICROWAVE ON

In

Enables microwaves emission 

High level enables

4

RESET

In

Reset after an alarm occurrence.

High level enables *

5

CW/PULSE MODE

In

Continuous/pulsed mode selection

High level selects pulsed mode

6

OVER DUTY

Out

Alarm

High level means alarm

7, 8, 

9, 10

In

Pulse pattern for pulsed mode, see 

forward.

11

Common 24Vdc

12

+24 V - ISOL

mirror for pin15

13

GROUND

14

GROUND

15

+24 V - ISOL

In

External Insulated 24 Vdc

16

MICROWAVE IS 

ACTIVATED

Out

mirror for pin3

17

HIGH VOLTAGE IS 

ACTIVATED

Out

mirror for pin2

18

unused

19

MW MODULE IS 

READY

Out

Raises 5 seconds after power on: once 

pre-heating is complete.

20, 

21

In

Pulse pattern for pulsed mode, see 

forward.

22

FAILURE COOLING 

MAGNETRON

Out

Alarm

High level means alarm

23, 

24

ALARM CONTACT

Out

Alarm contact

Open in case of alarm (or switch off)

25

VALUE LESS THEN 

SET VALUE

Out

Warning

High level means warning

POWER SECTION

HV SECTION

GM 140

POWER STAGE ON

HIGH VOLTAGE ON

MICROWAVE ON

HIGH VOLTAGE
FILAMENT

MW

ALARM

* After removing alarms cause set high for 1 sec. the reset signal to clear the alarm; a high value in this 

signal inhibits the latching of fhurter alarms.

Содержание GM 140

Страница 1: ...GM 140 SWITCHING POWER GENERATOR WITH PULSED OUTPUT CAPABILITY FOR 0 9 KW MAGNETRON 1 5 KW PEAK POWER TECHNICAL NOTE Issue October 2003...

Страница 2: ...he il Prodotto product name GM140 nome del prodotto GM140 model GM140T modello GM140T Complies with the following norms Soddisfa le seguenti norme EN 61010 1 1994 A2 1996 EN 61010 1993 A2 1995 EN55011...

Страница 3: ...rd exists it shall take precedence over all aspects of this generic standard The equipments described in this manual have been clas sified as industrial scientific and medical ISM radio frequency equi...

Страница 4: ...140 may drive the magnetron to reach peak power up to 1 5kWrf with a duty factor of 20 max corresponding to an average power of 300Wrf FRONT PANEL The front panel comprises the following see drw the e...

Страница 5: ...y operations the following rules must be adopted I the equipment must be grounded by the connector CONN 1 using the pin n 4 see the wiring drawings at page 10 and 11 II the three phase main supply typ...

Страница 6: ...r for pin15 13 GROUND 14 GROUND 15 24 V ISOL In External Insulated 24 Vdc 16 MICROWAVE IS ACTIVATED Out mirror for pin3 17 HIGH VOLTAGE IS ACTIVATED Out mirror for pin2 18 unused 19 MW MODULE IS READY...

Страница 7: ...nuous Pin 5 CONN 3 CW PULSE MODE OFF Pulsed with external generator Pin 5 CONN 3 CW PULSE MODE ON Pin 9 10 CONN 3 PULSE PATTERN PWM Amplitude 24 Vdc ton 0 1 10ms toff 1 100ms Max Duty Cycle 20 with hy...

Страница 8: ...remove the cover locate the interface board M284 see drawing next page pos 9 locate the fuse on the interface board replace the fuse with a new one with the same electrical characteristics install the...

Страница 9: ...pin size lll MOCPCX 0662614 4 Female pin size lll MOCPCX 0667402 6 1 Power board M282 800000282 7 1 Filament transformer 42ATT230 004 8 1 Main filter FL20AY01 9 1 Interface board M284 800000284 1 Conn...

Страница 10: ...GM 140 File GM140_r0eng October 2003 Technical note GM 140 page 9 of 12 Outside dimensions...

Страница 11: ...GM 140 page 10 of 12 File GM140_r0eng October 2003 Technical note GM 140 Pin out of CONN 1 2 3 with external pulse pattern generator POWER STAGE ON IS ACTIVATED 24V...

Страница 12: ...GM 140 File GM140_r0eng October 2003 Technical note GM 140 page 11 of 12 Pin out of CONN 1 2 3 with internal pulse pattern generator POWER STAGE ON IS ACTIVATED 24V...

Страница 13: ...rved Technical Assistance Alter s r l 42100 Reggio Emilia ITALY Tel 39 0522 553 820 fax 39 0522 553 577 Web www altersystem com Alarms and warnings When the GM140 is turned on without alarms the ALARM...

Отзывы: