GM 140
page 2
of 12
File: GM140_r0eng - October 2003 - Technical note: GM 140
GM 140
File: GM140_r0eng - October 2003 - Technical note: GM 140
page 3
of 12
Contents
A
Alarms 12
C
CE Declaration 1
Cleaning 7
Components Layout 8
Components List 8
E
Environmental conditions 4
Equipment installation 4
Equipment Ratings 3
F
Fuses replacement 7
Fuses specifications 4
G
General Description 3
General Information 2
H
Handling instructions 4
How to order 12
O
Outside dimensions 9
P
Physical characteristics 4
Pin out of CONN. # 1,2, 3 con segnale esterno 10
Pin out of CONN. # 1,2, 3 con segnale interno 11
T
Technical Assistance 12
W
Warnings 2
Wiring instructions 4
General Informations
This equipment satisfy the European Standard EN 61010-
1 (=CEI 66-5) (=IEC 1010-1) approved by CENELEC on
9/3/1993.
With reference to EN 61010-1 standard, note:
this appliance must be installed and serviced only by quali-
fied personnel.
The appliance must only be used by persons acquainted
with the regulations covering the application.
Note about EMC regulation: the generic emission standard
EN50081-2 (title: Electromagnetic compatibility - Generic
emission standard - Part 2: Industrial environment) sets
that “Where a relevant dedicated product or product-family
EMC emission standard exists, it shall take precedence over
all aspects of this generic standard”.
The equipments described in this manual have been clas-
sified as industrial, scientific and medical (ISM) radio-
frequency equipments and the related standard for the
emission is the EN55011 (=CEI110-6) (title: Limits and
methods of measurement of radio disturbance characteri-
stics of ISM equipment.)
With reference to EN55011 standard, this equipment is
included into Group 2 (Microwave generators, Thyristor
command equipment, Welding equipment, Induction
heating equipment or machine, Microwave industrial oven,
etc.), Class A (industrial environment): for this reason this
equipment shall not be used in the residential, commercial
and light-industrial environment.
The GM140, when properly installed, complies with the
limits of radio disturbance characteristic of a Group2, Class
A equipments as stated by EN55011.
Copy of the tests performed may be sent on request. Be
aware those tests cannot be used as a conformity certificate
of the user’s final equipment.
WARNINGS
The GM140 is a microwave generator with
output power of 0.3 kW @ 2.45 GHz.
People must not be exposed to the microwave
energy which may be given off by the magne-
tron or other microwave generator devices in
case of incorrect use or connections.
All microwave input and output connections,
waveguides, flanges, and couplings must be
made safe.