FI
SE
71
NO
FR
GB
DK
Displays
GB
Parameters
Index
Value
Meaning
Cooling in cooling
mode
P052
0
1 (default)
inactive
active
Heating in heating
mode
P053
0
1 (default)
inactive
active
Room with/without
external heat source
P054
0 (default)
1
2
without
with fireplace
with towel rail heating
Selection of heating
system
P055
0 (default)
1
2
3
4
Floor heating, standard
Floor heating, low energy
Radiator
Convector, passive
Convector, active
9 Displays
9.1
LED System key
Display
Meaning
Solution
Short flashing, orange
Radio transmission/
transmission attempt/
data transmission
Wait until the transmission has ended.
1 long lighting, green
Process confirmed
You can continue your operations.
1 long lighting, red
Process failed
Retry.
Short flashing, orange
(once every 10 sec-
onds)
Teach-in mode active
Enter the last four digits of the serial number of the
device for confirmation.
1 long lighting, red
Process failed or duty
cycle limit reached
Retry.
6x long flashing, red
Device defective
Observe the information in your app or contact your
specialist dealer.
1 lighting in orange and
1 lighting in green
Test indication
You can proceed after the test indication has gone out.
9.2 LED Heating zones
Display
Meaning
Solution
Slow flashing
Emergency operation
active
Change the batteries of the wall thermostat, perform a
radio test, reposition the wall thermostat if necessary,
replace a defective wall thermostat.
Double short flashing
Bad radio connection to
wall thermostat
Change the position of the wall thermostat or use a
repeater.