Altai Technologies Ltd. All rights reserved
Altai C1n Super WiFi CPE Installation Guide
TPS13-002_rev1.0
Figure 3-1 Grounding
Caution: Ground wires and hardware are not provided in the installation kit.
3.2.
LAN Cable for Outdoor Installation
STP cable with shielded connectors is required to protect the C1n against ESD. Follow
the instruction to crimp the cable:
1.
Cut about 4cm of the wire coating.
2.
Untwist eight wires with the order from left to right: Orange White, Orange, White
Green, Blue, White Blue, Green, White Brown, and Brown. The order will be the
same on both sides.
3.
Straighten eight wires and cut the wire with only 2cm extension
4.
Insert the wires into an RJ45 modular jack. The hook should face down. All eight
wires should touch the top of the jack.
5.
The foil and the shield of RJ45 connector should have direct contact
6.
Insert the modular jack into the crimping tool. Press down on the tool firmly.
3.3.
ESD Protection
The ESD (electrostatic discharge) can damage the electronic components. The ESD
can cause latent damage that results in premature failure even if components
remain function. The equipments must be properly grounded. The technical people
always need to wear the proper ESD grounding straps and make sure the ESD
grounding strap connecting to the ESD connector during equipment installation,
maintenance and repairs.