#30882-30883 / 30892-30893
trim kit for 2/3 ways thermostatic valve \ plaque pour valve thermostatique 2/3 voies
alt-aqua.com
MAINTENANCE
To Service The Cartridges
Shut off the main water supply, then remove all the
components from (7) to (21). (See Fig.5). Afterwards, shut
off the 2 check valves (1) by turning them clockwise with
a screwdriver. Unscrew the screw (3), the large nuts (5 &
6) and remove the cartridges (2 & 4).
To clean the cartridges, you may need to soak it in a
vinegar and water solution to remove lime build-up. If
replacement is necessary, insert the new cartridges and
screw the large nuts (5 & 6), the screw (3) back on.
DO
NOT OVERTIGHTEN.
To reinstall the components, just reverse the above
steps.
Entretien de les cartouches
Fermer l'alimentation d'eau principale et démonter
toutes les composantes de (7) à (21) (Voir Fig.5).
Ensuite,fermer les deux valves d'arrêt (1) en les tournant
dans le sens des aiguilles d'une montre avec un tourn-
evis. Dévisser la vis (3), les manchons de valves (5 & 6) et
enlever les cartouches (2 & 4).
Pour nettoyer les cartouches, l'imbiber dans une solution
d'eau et de vinaigre. Si nécessaire, insérer les nouvelles
cartouches revisser les manchons de les valves (5 & 6)
et la vis (3).
NE PAS TROP SERRER !
Pour remonter toutes les composantes, inverser les
étapes ci-haut.
1
3
4
2
5
9
14
7
8
10
12
13
6
11
15
16
17 19
18
21
20
Fig.5