MAINTENANCE
To service the cartridges
Shut off the main water supply, then remove all the
components from (7) to (21). (See Fig.5). Afterwards, shut
off the 2 check valves (1) by turning them clockwise with
a screwdriver. Unscrew the screw (3), the large nuts (5 &
6) and remove the cartridges (2 & 4).
To clean the cartridges, you may need to soak it in a
vinegar and water solution to remove lime build-up. If
replacement is necessary, insert the new cartridges and
screw the large nuts (5 & 6), the screw (3) back on. DO
NOT OVERTIGHTEN.
To reinstall the components, just reverse the above
steps.
Entretien des cartouches
Fermer l'alimentation d'eau principale et démonter
tous les composants de (7) à (21) (Voir Fig.5).
Ensuite,fermer les deux valves d'arrêt (1) en les tournant
dans le sens des aiguilles d'une montre avec un tourn-
evis. Dévisser la vis (3), les machons de valves (5 & 6) et
enlever les cartouches (2 & 4).
Pour nettoyer les cartouches, l'imbiber dans une
solution d'eau et de vinaigre. Si nécessaire, insérer
les nouvelles cartouches et revisser les manchons des
valves (5 & 6) et la vis (3). NE PAS TROP SERRER !
Pour remonter tous les composantes, inverser les
étapes ci-haut.
2
5
1
3
4
7
6
8
9
10
11
12
13
15
14
16
17
18
19
20
21
Fig.5