5. Programming
GEM80-500 Series Controller
GEM80-500 Technical Manual (T2025En)
(08/04)
Page 5-6
(l) Code
Conversion;
(m) Serial Port Alphanumeric Input and Output;
(n) Output
Functions;
(o) GEM 80-500 Additional Special Functions.
Details of the Standard Instruction Set are contained in the 'GEM
80 Programming
Manual', Publication No.T391. However, GEM
80-500 Additional Instructions, namely:
Set Coil, Reset Coil, Jump, Label and Seqelem, are not contained in the 'GEM
80
Programming Manual', Publication No. T391, but are detailed in the GEM80-400
Technical Manual T1614. Table 5-2 details the GEM80-500 Instruction Set.
Table 5-2
GEM80-500 Controller Instruction Set
Function
Instruction
GEM
80
Special
Function
Remarks Number
of
Instructions
Number of
Table Locations
used by VALUE
Execution
Time in
µ
s
N/O contact
---] [---
-
Functions as a normally open
relay contact
1 -
1.35
N/C contact
---]/[---
-
Functions as a normally
closed relay contact
1 -
1.35
Coil
---( )---
-
Functions as a relay coil
1
-
2.75
Set coil
---(S)---
-
Set retentive coil
1
-
-
Reset coil
---(R)---
-
Reset retentive coil
1
-
-
Output
OUT
-
Outputs 16-bit word to a
specified data table location
1 - 1
Time Delay
DELAY
-
Time range 100ms to 54
minutes
1 - 7
Counter
COUNT
-
Counter with a capacity of
32,767 (resettable)
1 - 12
1.
Relay
Replacement
Functions
Sequencer
SEQR
-
16-step Sequencer with reset
1
-
7
Logic AND
AND
-
Bit-by-bit ANDing of 2
×
16-
bit words
1 -
*0.3/0.85
Logic AND group
of words
ANDGRP
T24
Bit-by-bit ANDing of 2 groups
of 16-bit words
2
3
See Note 1
Logic OR
OR
-
Bit-by-bit ORing of 2
×
16-bit
words
1 -
*0.3/0.85
Logic OR group
of words
ORGRP
T25
Bit-by-bit ORing of 2 groups
of 16-bit words
2
3
See Note 1
Logic exclusive
OR
XOR -
Bit-by-bit XORing of 2
×
16-
bit words
1 -
*0.3/0.85
Exclusive OR
group of words
XORGRP T26
Bit-by-bit
XORing of 2 groups
of 16-bits words
2
3
See Note 1
Invert
INV
-
Inverts each bit of 16-bit word
1
-
0.2
Invert group
INVGRP
S25
Inverts each bit of a group of
16-bit word
2
3
See Note 2
2.
Logic
Functions
Sequence
diagnostics
SEQDIAG
T19
Enables automatic monitoring
of any sequence of events
2
11 + N
(See also Note 3)
<12
Addition
ADD
-
Addition of Floating
point/Integer values, limits
+32767 to-32768
1 -
*5.7/6.35
3.
Math
Functions
Array addition
ADDARAY
T12
Addition of arrays, limits
+32767 to -32768
2
3
See Note 4