background image

 

 

 

Airfield Lighting Systems UK Limited 

Aviation House, Russell Gardens, Wickford 

Essex SS11 8BF Tel +44 1702 547866 

[email protected]

 

www.alsukltd.co.uk

 

 
Monthly   

Check of the optical window, check for mechanical damage. 

                        Check for proper fixing of the light fixture in its base. 
 
Yearly   

Detailed inspection of the light fixture. 
Check of the body resistance, check for mechanical damage (for example 
cracks around prism windows). 

                 

Clean of the optical windows. 

4.2 Workshop Maintenance 

The workshop maintenance includes the following: 

  Replacement of light fixtures 

  Checking water tightness 

  Replacement of a prism and its gasket 

  Replacement of LED module 

 

CAUTION: 

Be sure to read and understand the safety instructions before you start. 

4.2.1 Tools and accessories 

The following standard tools and accessories are required for maintenance of the unit: 

  One angled socket spanner of 16 or 17 mm 

  One Torque limiting spanner with 16 or 17 mm socket 

  One hexagonal key (Allen key) of 3, 4, and 5 mm 

  Torx 10, 20, 25, and 30 

  Two large flat blade screwdrivers 

  Silicone grease 

  CC-Patron grease 

  One brush or cloth 

  Non-alcohol based cleaner 

Содержание RB/IN-RW(L)-C

Страница 1: ...ing Systems UK Limited Aviation House Russell Gardens Wickford Essex SS11 8BF Tel 44 1702 547866 sales alsukltd co uk www alsukltd co uk 12 Inch LED Inset Runway Edge Light with Circular Guidance Inst...

Страница 2: ...ribed in the manual may result in personal injury death or property and equipment damage Use this equipment only as described in the manual ALS cannot be held responsible for injuries or damages resul...

Страница 3: ...al errors ALS reserves the right to revise this manual from time to time in the contents thereof without obligation of ALS to notify any person of such revision or change Details and values given in t...

Страница 4: ...ce with standards 6 2 3 Features 6 2 4 Power and power factor 7 2 5 Dimensions and Weight 8 3 Installation 9 3 1 Tools and Material 9 3 2 Installation steps 9 3 3 Installation Bolt Torque 11 3 4Top Lo...

Страница 5: ...observe a warning may result in personal injury death or equipment damage DANGER Risk of electrical shock or ARC FLASH Disconnect equipment from line voltage Failure to observe this warning may result...

Страница 6: ...ble safety procedures required by your company industry standards and government or other regulatory agencies Install all electrical connections to local code Use only electrical wire of sufficient ga...

Страница 7: ...a system that contains malfunctioning components If a component malfunctions turn the system OFF immediately Allow only qualified personnel to make repairs Repair or replace the malfunctioning compone...

Страница 8: ...fixtures Light Fixture Ordering Code Optical Toe in Color Sketch Runway Edge Light width of runway is 45m RB IN WW L C Toe in 3 5 White White Runway Edge Light width of runway is 60m RB IN WW L C Toe...

Страница 9: ...width of runway is 45m RB IN WY L C Toe in 3 5 White Yellow RunwayEdge Light width of runway is 60m RB IN WY L C Toe in 4 5 White Yellow Runway Edge Light width of runway is 45m RB IN YW L C Toe in 3...

Страница 10: ...STANAG 3316 CAAC AC 137 CA 2015 01 CAAC AC 137 CA 2015 03 CAAC AC 137 CA 2017 03 2 3 Features Low protrusion of less than 6 3mm above ground level Modulized electrical driver and LED assembly for sim...

Страница 11: ...onal beam Optional Fail Open System 2 4 Power and power factor Light Fixture Ordering Code Power Power factor Runway Edge Light RB IN WW L C 65VA 0 90 Runway Edge Light RB IN WR L C 54VA 0 90 Runway E...

Страница 12: ...Airfield Lighting Systems UK Limited Aviation House Russell Gardens Wickford Essex SS11 8BF Tel 44 1702 547866 sales alsukltd co uk www alsukltd co uk 2 5 Dimensions and Weight Packing Data 6 11...

Страница 13: ...allation holes on the pavement wiring base embedding and mounting of lights The installation of light fixture has a great influence on the function and service life of the lights Proper and adequate t...

Страница 14: ...clean all contact surfaces of the light fixture and the base 2 Put the O ring gasket in the gasket track on the base 3 Connect the connector s of the light fixture to the base supply cable s Check tha...

Страница 15: ...ll the M10 bolts with lock washers per lock washer manufacturer s guidelines See Section 2 for Top Lock installation guidelines Achieve a full final torque of 26 9 Nm Use GTP600 lubricants to 33 Nm wi...

Страница 16: ...al pass on each bolt working clockwise from bolt 1 at 26 9 Nm Use GTP600 lubricant at 33 Nm torque 12 inch Inset Light 8 inch Inset Light WARNING The inset lights are designed to withstand a maximum t...

Страница 17: ...and nut will cause serious damage to product installation and cause a variety of safety risks Ignoring these warnings may result in equipment damage or airport foreign objects CAUTION When a light fix...

Страница 18: ...orkshop Maintenance The workshop maintenance includes the following Replacement of light fixtures Checking water tightness Replacement of a prism and its gasket Replacement of LED module CAUTION Be su...

Страница 19: ...its base 1 Use a torque socket wrench to remove the M10 30 bolts spring washer and flat washer 2 Pry up the lighting fixture with the 8 inches lighting fixture pry bar 3 After the light fixture and b...

Страница 20: ...nd the bottom cover 3 Remove the four M4 10 cross pan head screws and get out the LED light source assembly 4 Attach the new LED assembly on the prism pressing block in diagonal order with four m4 10...

Страница 21: ...3 Remove the six M5 16 hexagon screws and take out the prism pressing plate and prism gasket 4 Attach the prism pressing plate and prism gasket Confirm that the specifications of the prism and the re...

Страница 22: ...ure 1 If air leaks out continuously between bottom cover and upper cover or between prism and upper plate or between gas valve and bottom cover the light fixture is not watertight and must be repaired...

Страница 23: ...ixtures List of components and spare articles No Name Order type Description 1 Upper cover UC 12 RBC33 Upper cover for inset runway edge lights 2 Circuit board CB C01 Only used for nset runway edge li...

Страница 24: ...uk BC 12 II WW Used for RB IN WW L 2 plugs BC 12 II CW Used for RB IN WR L RB IN RW L RB IN WY L or RB IN YW L 2 plugs BC 12 II CC Used for RB IN YR L or RB IN RY L 2 plugs 1 Upper cover 2 Circuit bo...

Отзывы: