Alpine TR42 Direct Vent Gas Fireplace
WIRING
WIRING THE FIREPLACE
NOTE: Proper grounding must be maintained on the
appliance and on the blower assembly.
NOTE: Do not allow any wiring to rest against the
appliance as fire danger may result.
NOTE: DO NOT connect any electricity to the main
gas control valve wiring. Valve damage will certainly
occur.
NOTE: Electrical wiring must be installed by a
licensed electrician.
The appliance is also equipped with a millivolt system that
controls the main gas control valve. A low voltage two
strand wire set needs to be routed from the main gas
control valve to the desired position of the wall switch.
Some prefer the switch be co-located with the power
switch for the optional blower.. If this choice is made, a
DIVIDED double gang electrical box must be installed. (A
standard (non-divided) double gang box cannot be used.)
NOTE: Electrical wiring must be installed by a licensed
electrician.
NOTE; The appliance must be electrically grounded in
accordance with the local codes, or in the absence of
local codes with the current National Electrical Code,
ANSI/NFPA 70.
OPTIONAL BLOWER
The fireplace needs to have a 110-120 VAC power supply,
preferably on a switch, wired to the factory installed junc-
tion box before the fireplace is permanently installed.
The
optional blower requires this power source to operate.
Use blower kit 430-917
2 Conductor
Plug & Recepticle
Appliance Cord
w/Fiberglass Shield
Secured to Floor
White
Black
Ground
Black
120 v. Power Source
(Switched)
High Temperature Wire
With Fiberglass Shield
Secured to Floor