(4) Adjustment Procedures
Step
Description
Connection
Signal Generator
Dial Control
Test Point /
P.W.Board
Coordinates
Adjustment
1
Signal Meter
Auto
Adjustment
(FM)
Figure 3
(1)
87.5MHz ,
26dBµ
(Mod. OFF)
87.5MHz
(3-F)
(5-D)
AutoAdjustment:
After settingup of Signal Genarator,
short GND andTP608(Pull-Down)
for 2~3 seconds.
(2)
87.5MHz ,
26dBµ
(Mod. OFF)
87.5MHz
(3-F)
(5-D)
Proceedsame AutoAdjustmentof step
(1) understep (2).
(SPEC) TP002: 1.5±0.1V: OK
(SPEC) TP002: others 1.5±0.1V: NG
NOTE : NG : Proceedsame Auto
Adjustmentof step (1)
understep (3).
(3)
87.5MHz ,
21~23dBµ
(Mod. OFF)
87.5MHz
(3-F)
(5-D)
Proceedsame AutoAdjustmentof step
(1) understep (3).
(4)
87.5MHz ,
26dBµ
(Mod. OFF)
87.5MHz
(3-F)
(5-D)
Proceedsame AutoAdjustmentof step
(1) understep (4).
2
Signal Meter
Auto
Adjustment
(MW)
Figure 4
(1)
999kHz ,
34dBµ
(Mod. OFF)
999kHz
(3-F)
(5-D)
AutoAdjustment:
After settingup of Signal Genarator,
short GND andTP608(Pull-Down)
for 2~3 seconds.
(2)
999kHz ,
34dBµ
(Mod. OFF)
999kHz
(3-F)
(5-D)
Proceedsame AutoAdjustmentof step
(1) understep (2).
(SPEC) TP002: 1.0±0.1V: OK
(SPEC) TP002: others 1.0±0.1V: NG
NOTE : NG : Proceedsame Auto
Adjustmentof step (1)
understep (3).
(3)
999kHz ,
29~31dBµ
(Mod. OFF)
999kHz
(3-F)
(5-D)
Proceedsame AutoAdjustmentof step
(1) understep (3).
(4)
999kHz ,
34dBµ
(Mod. OFF)
999kHz
(3-F)
(5-D)
Proceedsame AutoAdjustmentof step
(1) understep (4).
CDM-9825RB
TO CONTENTS
- 8 -