Description of IC Terminal
D784216AGF :
IC601
No.
Symbol
I/O
Terminal Description
1
2
3
/ LCD RST
O
RESET signal output terminal to LCD Driver (LC75883).
4
LCD DI
O
Serial Data signal output terminal to LCD Driver (LC75883).
5
LCD CE
O
Chip Enable signal output terminal to LCD Driver (LC75883).
6
LCD CLK
O
Serial Clock signal output terminal to LCD Driver (LC75883).
7
LCD DO
I
Serial Data signal input terminal from LCD Driver (LC75883).
8
NC
-
No connect terminal.
9
VDD
-
Power supply terminal.
10
POWER IC ON
O
STBY CONT signal output terminal to Power IC.
11
NOSE POWER
O
Power supply control signal output terminal of LCD Driver and Remote Control.
12
NC
-
No connect terminal.
13
POWER CONT
O
Power supply control signal output terminal of Audio and Key lighting.
14
NC
-
No connect terminal.
15
SD SW
O
Time Constant switching terminal of High Speed PLL active by AF Check etc.
16
50k REF
O
LPF switching output terminal at RDS active.
17
NC
-
No connect terminal.
18
V-CONT
O
Power supply control signal output terminal of Servo/Mechanism.
#1,$1 REMOCON
I
Remote Control Data input terminal.
%1,&1 NC
20
21
22
Vpp
-
Flash Memory writing terminal.
23
24
25
RDS SCL
O
RDS Clock output terminal from RDS Decoder (SAA6588T).
26
RDS SDA
I/O
RDS Data input/output terminal to RDS Decoder (SAA6588T).
27
E.VOL SCL
O
Serial Clock signal output terminal to E.VOL (TDA7404).
28
E.VOL SDA
I/O
Serial Data signal input/output terminal to E.VOL (TDA7404).
29
PLL CE
O
Communication CONT signal output terminal to PLL (LC72191M).
30
PLL DO
I
Data input terminal from PLL (LC72191M).
31
SEL1
I
Model selection input terminal.
32
/CD STBY
O
Stand-by control signal output terminal of Mechanism u-COM.
33
0 MUTE-DET
I
0-bit MUTE signal input terminal.
34
/CD RST
O
RESET signal output terminal of Mechanism u-COM.
35
/CD CS
O
Communication control signal output terminal of Mechanism u-COM.
36
V-Link Select
I
V-Link set up input terminal.
37
VDD
-
Power supply terminal.
38
X2
39
X1
40
GND
-
GND connect terminal.
41
XT2(NC)
-
No connect terminal.
42
GND
-
GND connect terminal.
43
/RESET
I
System RESET signal input terminal.
44
BATT DET
I
BATT detect signal input terminal. (Compulsion Stand-by)
NOTE : #1 : For CDM-9803R Model Only, $1 : For CDM-9803RM Model Only, %1 : For CDE-9802RB Model Only,
&1 : For CDE-9801R Model Only, Others : Common.
19
-
No connect terminal.
NC
-
No connect terminal.
-
Main System Clock OSC input terminal. (12.288MHz)
NC
NC
-
No connect terminal.