background image

6

General Information

Relative humidity is important to your health and home as
proper humidification helps reduce respiratory difficulties
and helps improve the indoor air quality.
A good relative humidity is one just high enough to barely
start condensation along the lower edges or lower
corners of the windows. More than that can be damag-
ing.
Frequent fogging or excessive condensation on inside
windows indicates the indoor humidity level is too high
for outdoor weather conditions. Damage to the building
may result if the condition persists. Condensation on
inside of storm windows indicates loose inside windows.
Adding weather-stripping to tighten inside windows
usually corrects this problem.
The following table shows the recommended maximum
indoor humidity in relationship to the outdoor tempera-
tures.

Outdoor

Humidity

Temperature

Single -Paned Double-Paned

Glass

Glass

+30°F

30%

50%

+20°F

20%

40%

+10°F

15%

35%

0°F

10%

30%

-10°F

5%

25%

-20°F

5%

20%

-30°F

3%

18%

For Propane (LP) Installations Only

For furnaces operating on propane, please review the fol-
lowing warnings before use.

WARNING

To avoid death, personal injury or property damage
due to explosion or fire, install a gas detecting
warning device. Since the odorant  in propane gas
can be reduced by iron oxide (rust), a gas detecting
warning device is the only reliable method to detect
propane gas leaks.

WARNING

If  the gas furnace is installed in a basement, an
excavated area or a confined space, it is strongly
recommended to contact a propane supplier to install
a gas detecting warning device in case of a gas leak.

• Since propane gas is heavier than air, any leaking

gas can settle in any low areas or confined
spaces.

• Propane gas odorant may fade, making the gas

undetectable except with a warning device.

 

WARNING

An undetected gas leak will create a danger of
explosion or fire. If the presence of gas is suspected,
follow the instructions on the front cover of this
manual. Failure to do so could result in SERIOUS
PERSONAL INJURY OR DEATH.

Содержание 80% SINGLE-STAGE COUNTERFLOW FURNACE

Страница 1: ...tained Take time to familiarize yourself with the information concerning furnace installation features operation and maintenance contained within this manual 80 SINGLE STAGECOUNTERFLOWFURNACE USER S I...

Страница 2: ...he customer This includes all safety precautions and related items Prior to actual installation thoroughly familiarize yourself with this Instruction Manual Pay special attention to all safety warning...

Страница 3: ...re in a safe place for future reference THE INSTALLATION AND SERVICING OF THIS EQUIPMENT MUST BE PERFORMED BY QUALIFIED EXPERIENCED TECHNICIANS ONLY WARNING Should overheating occur or the gas supply...

Страница 4: ...arances for the furnace are always maintained These clearances are listed on the Furnace Clearance Label attached to the fur nace unit If any question develops contact the in staller of the furnace or...

Страница 5: ...1 Headaches Nausea Dizziness Flu Like Symptoms 2 Excessive humidity heavily frosted windows or a moist clammy feeling in the home 3 Smoke from a fireplace will not draw up the chimney 4 Flue gases tha...

Страница 6: ...F 20 40 10 F 15 35 0 F 10 30 10 F 5 25 20 F 5 20 30 F 3 18 For Propane LP Installations Only For furnaces operating on propane please review the fol lowing warnings before use WARNING To avoid death p...

Страница 7: ...cal components are contained in both compartments To avoid electrical shock injury or death do not remove any internal compartment covers Contact a qualified servicer at once if an abnormal condition...

Страница 8: ...following the five minute waiting period in Step 7 follow the instructions on the front page of this manual If gas can not be smelled Push the selector switch to ON 9 Replace the door on the front of...

Страница 9: ...problem causing the control to open can be corrected Roll out Limit Switches The roll out limit switches are normally closed electri cally manual reset temperature activated sensors The switches are m...

Страница 10: ...ll furnace components are in proper working order and that the heating system functions appropriately Particular attention should be paid to the following items Repair as necessary Flue pipe system Ch...

Страница 11: ...throwaway filters If dirty these filters must be thrown away and replaced with two new similar size throwaway filters b Other installations will have two permanent filters Wash rinse and dry dirty pe...

Страница 12: ...URING NUMBER P _ _ _ _ _ _ _F SERIAL NUMBER _ _ _ _ _ _ _ _ _ _ To obtain the proper labels the Model Manufacturing Number and Serial Number of the unit must be supplied These numbers are recorded on...

Отзывы: