Filtration and Ozone
On circulation systems, the ozone will run with the circulation pump. The system is
factory-programmed with one filter cycle that will run in the evening (assuming the time-
of-day is properly set) when energy rates are often lower.
The filter time and duration are programmable. A second filter cycle can be enabled as
needed. At the start of each filter cycle, Pump 2 will run briefly to purge its plumbing to
maintain good water quality.
Freeze Protection
In colder climates, an optional additional freeze sensor may be added to protect against
freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor
protection acts similarly except with the temperature thresholds determined by the switch.
See your dealer for details.
Clean-Up Cycle (Optional)
When a pump is turned on by a button press, a clean-up cycle begins 30 minutes after
the pump is turned off or times out. The pump and the ozone generator will run for 30
minutes or more, depending on the system. On some systems, you can change this
setting.
Temperature Operation
Adjusting the Set Temperature
When using the panel for Temperature control, pressing Up Arrow (Warm) or Down
Arrow (Cool) will cause the temperature to flash.
Pressing the Up Arrow (Warm)/ Down Arrow (Cool) buttons again will adjust the set
temperature in the direction indicated on the button. When the LCD stops flashing, the
spa will heat to the new set temperature when required.
If the panel has a single temperature button, pressing the button will cause the
temperature to flash. Pressing the button again will cause the temperature to change in
one direction (e.g. UP). After allowing the display to stop flashing, pressing the Warm/Cool
Buttons will cause the temperature to flash and the next press will change the temperature
in the opposite direction (e.g. DOWN).
Warm/Cool buttons will cause display to be flashing.
Press the Warm (Up) or Cool (Down) buttons repeat until desired temperature is reached.