If the installation does not comply with Grade 1, 2 or 3, the labels MUST be removed or 

made clear in another way that the installation is non-compliant! 

The serial number must not be removed. 

AT-100  

The AT-100 access reader is a DESFire EV2 access control reader for the UNii control panel. The 

AT-100 can be used for access control applications and/or arming and disarming of the UNii 

control panel. 

 

System requirements 

The AT-100 access reader can only be used on the UNii control panel and supports DESFire EV2 

tagss (art.code 008072 and 008074) and cards (008075). 

 

To ensure proper functioning of the equipment, the environment of the AT-100 must be compliant 

with certain conditions. 

 

Caution:  

The AT-100 operates between a temperature and humidity of -30°C and + 85°C 

and 20 ~ 90%  

RH non-condensing. 

 

Wiring 

The AT-100 access reader is available in a version with terminal connections (art.code 004630) 

and a version with 3m cable (art.code 004639) and must be connected to a card reader interface 

(art.code: 004628) or Door controller (art.code 004650/004651) using shielded twisted-pair CAT5E 

cable. The maximum cable length between the AT-100 access reader and card reader interface or 

Door controller is 100m. 

 

Spacers 

 

Spacer name:   

 

Article code: 

Spacer  

 

 

004634 

Spacer protector 

 

004635 

Rubber seal (10 pcs)   

004636  

 

 

 

The spacer can be used when mounting the access reader on a metal surface, placing the reader 

on the metal surface can influence the reading distance.  

 

The spacer protector is like the spacer but offers extra protection on both sides of the access 

reader. The spacer protector can be used when the access reader is mounted in a harsh 

environment.  

 

Содержание UNii AT-100

Страница 1: ...UNii Door controller Installation manual UNii Deur controller installatie handleiding English page 2 Nederlands pagina 21 ...

Страница 2: ...tification 8 AT 100 9 System requirements 9 Wiring 9 Measurements 10 Mounting steps 11 Connections and indicators 12 Connecting Card Reader interface 14 AT 100 with pigtail 14 AT 200P 15 System requirements 15 Wiring 15 Measurements 16 Location 16 Mounting steps 16 Connections 17 Technical specifications AT 100 200P 17 Connecting AT 100 and AT 200P to Card Reader Interface 18 Connecting AT 100 and...

Страница 3: ...3 EN AT 400P 21 Mounting steps 21 ...

Страница 4: ...n independent voltage and emergency power supply and is supplied in a metal housing Mounting The metal enclosure must be securely fastened using 3 screws 4 2 x 60 mm and suitable plugs For a surface other than brick suitable screws and if necessary plugs must be used The screw holes are located at the bottom left and right of the cabinet and one slotted hole in the middle of the cabinet See the fi...

Страница 5: ...7 RS485 bus IN 8 RS485 bus OUT 9 OSDP connection 10 Reader 1 Door activation Relay 11 Reader 2 Door activation Relay 12 External AUX power 13 Battery connection 14 Power supply connection 15 Input expander connector 16 Output expander connector 17 Tamper switch connection 18 Jumpers 19 Low battery indicator 20 230V power OK 21 UNii RS 485 bus communication error 22 UNii RS 485 bus communication OK...

Страница 6: ...rsion The outgoing power supply AUX socket No 12 is used to power an electric door strike The door reader Wiegand connections no 2 and 5 are equipped with a 12VDC power supply terminal for powering the door readers In the 12V version 1 5A is available externally for connecting door readers door strikes etc In the 24V version 800mA is available externally for connecting door readers door strikes et...

Страница 7: ...th the protective earth Ensure that this connection is properly connected when closing the cabinet This equipment may only be installed by qualified personnel and must be kept out of reach of children Always ensure that the alarm system is properly earthed If there are doubts about the grounding check it carefully A good grounding is essential for the proper removal of electrical interference Jump...

Страница 8: ...protects the RED led output of door reader 2 F3 100mA polyfuse protects the GREEN led output of door reader 2 F4 500mA polyfuse protects the internal 3V3 power supply F9 100mA polyfuse protects the OC output of door reader 2 F10 100mA polyfuse protects the GREEN led output of door reader 1 F11 100mA polyfuse protects the OC output of door reader 1 F12 750mA polyfuse protects the 12V OSDP bus suppl...

Страница 9: ...een a temperature and humidity of 30 C and 85 C and 20 90 RH non condensing Wiring The AT 100 access reader is available in a version with terminal connections art code 004630 and a version with 3m cable art code 004639 and must be connected to a card reader interface art code 004628 or Door controller art code 004650 004651 using shielded twisted pair CAT5E cable The maximum cable length between ...

Страница 10: ...rface like a brick wall Measurements Location Determine the location where the AT 100 card reader should be installed Please note that there is a maximum cable length of 100m between the access reader and the card reader interface or Door controller Keep a minimum distance of 20cm between AT 100 and AT 200P access readers The AT 100 should preferably not be installed directly on a metal surface If...

Страница 11: ...iate screws and plugs The head of the screws must be at least 6mm wide Please notice that the screw hole of the access reader must be placed on the underside Remove the 9 pin terminal connector from the back of the access reader Connect the cable to the connector For correct wiring see connections and indicators Place the connector back on the back of the access reader Place the card reader on top...

Страница 12: ...12 EN Connections and indicators The AT 100 access reader contains the following indicators and connections ...

Страница 13: ...13 EN ...

Страница 14: ...te Ground A x RS485 A not used B x RS485 B not used LED Orange Activate LED input BUZ Gray Activate buzzer input TAMP x D0 Green D0 input Card reader interface D1 Yellow D1 input Card reader interface The AT 100 accepts a power between 5 0 and 16 0 VDC A higher input voltage results in lower power consumption and ensuring cost efficient wiring with a smaller conductor diameter When using an extern...

Страница 15: ...en a temperature and humidity of 30 C and 85 C and 20 90 RH non condensing Wiring The AT 200P access reader contains terminal connections on the back and must be connected to a card reader interface art code 004628 or Door controller art code 004650 004651 using shielded twisted pair CAT5E cable The maximum cable length between the AT 200P access reader and card reader interface or Door controller...

Страница 16: ...ry please use a outside spacer see wiring spacers to achieve optimal reading distance Mounting steps Mount the access reader preferably on a flat surface Pull the cable through the mounting plate of the AT 200P reader The screw hole of the card reader should be placed on the underside Mount the back plate of the card reader to the wall of outlet using the appropriate plugs and screws When not remo...

Страница 17: ...fications AT 100 200P AT 100 AT 200P Power supply 5 16 VDC 25mA 5 16 VDC 25mA Current drain 125mA 12VDC 175mA 12VDC Dimensions 142 x 45 x 22mm 80 x 80 x 19mm IP rating IP54 IP64 IP64 Operating temperature 40 to 85ºC 40 to 85ºC Connection 9 pin terminal cable 7 pin terminal Output Wiegand Wiegand Reader technology DESFire EV2 DESFire EV2 Tag distance 20 70mm 50 70mm User interface LED Buzzer LED Bu...

Страница 18: ...dress 1 Off Off Off Off X Address 2 On Off Off Off X Address 3 Off On Off Off X Address 4 On On Off Off X Address 5 Off Off On Off X Address 6 On Off On Off X Address 7 Off On On Off X Address 8 On On On Off X Address 9 Off Off Off On X Address 10 On Off Off On X Address 11 Off On Off On X Address 12 On On Off On X Address 13 Off Off On On X Address 14 On Off On On X Address 15 Off On On On X Brid...

Страница 19: ...D0 D0 Wiegand Clock Data Tamp T Tamper contact Buz OC Buzzer driver LED G R Led Driver Green Led Driver Red 0 0 GND 12 VDC Rotary switch Jumpers Rotary setting Auto addressing 0 Fixed addressing 1 F TXD RXD Debug Flashing TAMP Bridge tamper casing PROG Debug Flashing RESET Reset module ISP Debug Flashing ...

Страница 20: ...ontroller etc Right after applying the voltage all 3 LED s lights and the buzzer beeps Right after the yellow LED is lit and the buzzer is silent 9 30 42 VDC 30mA 0V GND N A Wiegand D0 Data Wiegand D1 Clock External buzzer 0V active External controlling red LED 0V active External controlling green LED 0V active ...

Страница 21: ...hould never exceed 24VDC Black GND 0V Yellow N A White Wiegand D1 Clock Green Wiegand D0 Data Orange External controlled Red LED 0V active Brown External buzzer 0V active Blue External controlled Green LED 0V active Note Right after applying the voltage all LED s lights and the buzzer sounds do not touch the reader untill the yellow LED is lit and the buzzer is silent ...

Страница 22: ...UNii Door controller Installation manual UNii Deur controller installatie handleiding English page 2 Nederlands pagina 21 ...

Страница 23: ...Identificatie 29 AT 100 30 Systeemeisen 30 Bekabeling 30 Afmetingen 31 Locatie 31 Montage stappen 32 Aansluitingen en indicatoren 33 Aansluitingen 34 AT 100 met pigtail 34 AT 200P 35 Systeemeisen 35 Bekabeling 35 Afmetingen 36 Locatie 36 Montage stappen 36 Aansluitingen 37 Technische specificities AT 100 200P 37 AT 100 en AT 200P op kaartlezer interface aansluiten 38 AT 100 en AT 200P op Deur cont...

Страница 24: ...24 NL Aansluitingen 42 ...

Страница 25: ...age De metalen behuizing moet veilig vastgeschroefd worden met 3 schroeven 4 2 x 60 mm en bijpassende pluggen Voor een andere ondergrond dan steen moeten daarvoor geschikte schroeven en indien nodig pluggen gebruikt worden De schroefgaten bevinden zich beneden zowel links als rechts en één sleutelgat bevindt zich in het midden van de behuizing boven Teken het gat van sleutelgat gaf en plaats een s...

Страница 26: ...zer 2 LED en OC uitgang 7 RS485 bus IN 8 RS485 bus UIT 9 OSDP connectie 10 Lezer 1 Deur Relais 11 Lezer 2 Deur Relais 12 Externe AUX power 13 Batterij connectie 14 Voeding connectie 15 Ingang Expander 16 Uitgang Expander 17 Sabotageschakelaar extern 18 Jumpers 19 Lage batterij indicatie 20 230V stroom OK 21 RS 485 bus comm Fout 22 RS 485 bus comm OK 24 Watchdog LED ...

Страница 27: ...ktrische deurvergrendeling aansluit of uw de juiste versie heeft De uitgaande voeding AUX klem nr 12 wordt gebruikt voor het voeden van de elektrische deurvergrendeling De deurlezer Wiegand aansluitingen klem nr 2 en 5 zijn uitgerust met een 12VDC of 24VDC voeding In de 12VDC versie is 1 5A beschikbaar de deurlezers en deurvergrendelingen in de 24VDC versie is 800mA beschikbaar Wanneer gebruik wor...

Страница 28: ...t is aangesloten wanneer je de behuizing sluit Deze apparatuur mag alleen door daarvoor bestemde personen worden geïnstalleerd en moet buiten het bereik van kinderen blijven Controleer altijd of de Deur Controller juist is geaard Bij twijfel over de aarding controleer dit dan voorzichtig Een goede aarding is essentieel voor het juist verhelpen van een elektrische storing Jumpers Het moederbord hee...

Страница 29: ... uitgang van deur lezer 2 F4 500mA polyfuse beschermd de interne 3v3 voeding F9 100mA polyfuse beschermd de OC uitgang van deur lezer 2 F10 100mA polyfuse beschermd de groene led uitgang van deur lezer 1 F11 100mA polyfuse beschermd de OC uitgang van deur lezer 1 F12 750mA polyfuse beschermd de 12V OSDP bus levering Accu 5A glas zekering 6x 32mm 230V 315mA glas zekering 5 x 20mm Service De Unii De...

Страница 30: ...erface art nr 004628 of deur controller art nr 004650 004651 met een afgeschermde twisted pair CAT5E kabel De maximale kabellengte tussen de AT 100 toegangslezer en de kaartlezer interface of deur controller is 100m Accessoires Accessoire naam Artikelnummer Afstandplaat 004634 Beschermkap 004635 Rubber plaat IP65 10 stuks 004636 De afstandplaat kan gebruikt worden als de toegangslezer op een metal...

Страница 31: ... er een maximale kabellengte is van 100m tussen de toegangslezer en de kaartlezer interface of deur controller Houd een maximale afstand van 20cm tussen toegangslezers De AT 100 bij voorkeur niet installeren op een metaal ondergrond als dit niet anders kan gebruik dan een afstandplaat om optimale leesafstand te behouden ...

Страница 32: ...vlak met de juiste schroeven en pluggen De kop van de schroeven moet minimaal 6mm breed zijn Houd er rekening mee dat het schroefgat van de toegangslezer aan de onderkant geplaatst moet worden Verwijder de 9 polige klemmenstrook van de achterzijde van de toegangslezer Sluit de kabel aan op de klemmenstrook en plaats de klemmenstrook weer terug op de achterkant van de toegangslezer Plaatst de kaart...

Страница 33: ...33 NL Aansluitingen en indicatoren De AT 100 heeft de volgende aansluitingen en indicatoren ...

Страница 34: ...A x RS485 A niet gebruikt B x RS485 B niet gebruikt LED Oranje LED sturing BUZ Grijs Buzzer storing TAMP x D0 Groen D0 input Card Reader interface D1 Geel D1 input Card reader interface De AT 100 moet gevoed worden met een 5 16VDC voedingsspanning Een hogere spanning resulteert in een lager stroomverbruik en kan een dunnere kabel toegepast worden Bij gebruik van een externe voeding moet deze voldo...

Страница 35: ... C en vochtigheid van 20 90 RV niet condenserend Bekabeling De AT 200P toegangslezer heeft een klemmenstrook op de achterzijde van de lezer en moet worden aangesloten op een kaartlezer interface art nr 004628 of deur controller art nr 004650 004651 met een afgeschermde twisted pair CAT5E kabel De maximale kabellengte tussen de AT 200P toegangslezer en de kaartlezer interface of deur controller is ...

Страница 36: ...oos gemonteerd worden of direct op de muur Teken de 2 montagegaten af mbv de achterplaat van de toegangslezer en boor de 2 gaten De diameter van de gaten is 6mm voor pluggen in een stenen muur en 3mm in houten muren Haal de kabel door de achterplaat en afstandplaat of rubberen pad indien van toepassing Maak de achterplaat vast aan het oppervlak met de juiste schroeven en pluggen De kop van de schr...

Страница 37: ...e specificities AT 100 200P AT 100 AT 200P Voeding 5 16 VDC 25mA 5 16 VDC 25mA Afvoer 125mA 12VDC 175mA 12VDC Afmetingen 142 x 45 x 22mm 80 x 80 x 19mm IP rating IP54 IP64 IP64 Temperatuur bij gebruik 40 to 85ºC 40 to 85ºC Connectie 9 pin terminal cable 7 pin terminal Uitvoer Wiegand Wiegand Lees technologie DESFire EV2 DESFire EV2 Tag afstand 20 70mm 50 70mm User interface LED Buzzer LED Buzzer ...

Страница 38: ...kaartlezer interface aansluiten Toegangslezer Kaartlezer interface D1 D1 Wiegand Clock Data D0 D0 Wiegand Clock Data TAMP T Sabotage Contact Buz OC Buzzer aansturing LED G R Led aansturing Groen Led aansturing Rood 0 0 GND 12 VDC ...

Страница 39: ...5 Off Off On Off X Address 6 On Off On Off X Address 7 Off On On Off X Address 8 On On On Off X Address 9 Off Off Off On X Address 10 On Off Off On X Address 11 Off On Off On X Address 12 On On Off On X Address 13 Off Off On On X Address 14 On Off On On X Address 15 Off On On On X Bridge tamper reader On TXD RXD Debug Flashing TAMP Overbrug sabotage PROG Debug Flashing RESET Reset module ISP Debug...

Страница 40: ...D0 Wiegand Clock Data Tamp T Sabotage contact Buz OC Buzzer aansturing LED G R Led aansturing Groen Led aansturing Rood 0 0 GND 12 VDC Rotary switch Jumpers Rotary setting TXD RXD Debug Flashing Auto addressing 0 TAMP Overbrug sabotage Fixed addressing 1 F PROG Debug Flashing RESET Reset module ISP Debug Flashing ...

Страница 41: ...ntroller etc Direct na het inschakelen van de spanning lichten alle 3 LED s op en piept de buzzer Vervolgens gaat de gele LED branden en is de buzzer stil 9 30 42 VDC 30mA 0V GND N A Wiegand D0 Data Wiegand D1 Clock External buzzer 0V active External controlling red LED 0V active External controlling green LED 0V active ...

Страница 42: ...ld never exceed 24VDC Black GND 0V Yellow N A White Wiegand D1 Clock Green Wiegand D0 Data Orange External controlled Red LED 0V active Brown External buzzer 0V active Blue External controlled Green LED 0V active Opmerking Direct na het inschakelen van de spanning gaan alle LED s branden en klinkt de buzzer raak de lezer niet aan totdat de gele LED brandt en de buzzer stil is ...

Страница 43: ...components Most of the components used can be recycled The symbol means that this product should be recycled separately and not put in the normal waste bin together with normal household waste This product can be handed over to your local city council disposal point shop or supplier ALPHATRONICS BV 2020 Version 1 21 06 04 2022 ...