Measurements
Location
•
Determine the location where the AT-200P keypad access reader should be installed.
Please note that there is a maximum cable length of 100m between the keypad access
reader and the card reader interface or Door controller.
•
Keep a minimum distance of 20cm between AT-100 and AT-200P access readers.
•
The AT-200P should preferably not be installed directly on a metal surface. If this is
necessary, please use a (outside) spacer (see wiring: spacers) to achieve optimal reading
distance.
Mounting steps
Mount the access reader preferably on a flat surface.
•
Pull the cable through the mounting plate of the AT-200P reader.
•
The screw hole of the card reader should be placed on the underside.
•
Mount the back plate of the card reader to the wall of outlet, using the appropriate plugs
and screws.
•
When not removed, remove the orange-colored sticker on the Buzzer.
•
Click the front of the card reader at the top of the mounting plate.
•
Attach the front of the card reader to the mounting plate with the supplied 'special
mounting bolts.