18
EN
Connecting AT-100 and AT-200P to Card Reader Interface
Reader
Interface controller
D1
D1
Wiegand Clock/Data
D0
D0
Wiegand Clock/Data
TAMP
T
Tamper Contact
Buz
OC
Buzzer driver
LED
G
R
Led Driver (Green)
Led Driver (Red)
0
0
GND
+
+
12 VDC
Dipswitch instelling Card Reader Interface
1
2
3
4
5
6
Auto addressing
On On On
On
X
Address 1
Off Off Off Off X
Address 2
On Off Off Off X
Address 3
Off On Off Off X
Address 4
On On Off Off X
Address 5
Off Off On
Off X
Address 6
On Off On
Off X
Address 7
Off On On
Off X
Address 8
On On On
Off X
Address 9
Off Off Off On
X
Address 10
On Off Off On
X
Address 11
Off On Off On
X
Address 12
On On Off On
X
Address 13
Off Off On
On
X
Address 14
On Off On
On
X
Address 15
Off On On
On
X
Bridge tamper reader
On
TXD/RXD
Debug/Flashing
TAMP
Bridge tamper casing
PROG
Debug/Flashing
RESET
Reset module
ISP
Debug/Flashing
Содержание UNii AT-100