Alphatech Brave series Скачать руководство пользователя страница 4

 

 

 

Table of Contents 

1

 

BASIC FEATURES ............................................................................................. 6

 

1.1

 

F

EATURES

 ............................................................................................ 6

 

1.2

 

T

ERMINOLOGY

 ...................................................................................... 7

 

1.3

 

B

RAVE 

S

LIM

DP

 VERSIONS AND DIFFERENCES

 ......................................... 8

 

1.4

 

U

NIT FEATURES

 ..................................................................................... 8

 

2

 

INSTALLATION ................................................................................................. 9

 

2.1

 

O

PENING

,

 WIRING

,

 WALL MOUNTING AND SETTINGS

 ................................. 9

 

2.1.1

 

Name card panel ....................................................................................... 9

 

2.1.2

 

Uncover control elements ......................................................................... 9

 

2.1.3

 

Wiring and wall mounting ...................................................................... 10

 

2.1.4

 

Switches .................................................................................................. 12

 

2.1.5

 

Voice level ............................................................................................... 13

 

2.2

 

L

OCATION OF  

D

OORPHONE COMPONENTS

 ........................................... 14

 

2.3

 

C

HANGING NAME CARDS

 ...................................................................... 15

 

2.4

 

F

INAL CLOSING OF 

D

OORPHONE

 ........................................................... 15

 

2.4.1

 

Covering control elements ...................................................................... 15

 

2.4.2

 

Replacing name card panel .................................................................... 15

 

2.5

 

C

ONNECT THE 

K

EYBOARD

 ................................................................... 16

 

2.6

 

C

ODE RELAY 

(COSW) ......................................................................... 17

 

2.7

 

O

THER ACCESSORIES

 .......................................................................... 18

 

2.7.1

 

Time Relay .............................................................................................. 18

 

2.7.2

 

Power supply 12V AC ............................................................................. 18

 

2.7.3

 

Power supply 12V DC ............................................................................. 18

 

2.7.4

 

USB Programming cable ........................................................................ 18

 

3

 

DOOR ENTRY SYSTEM OPERATION ........................................................ 19

 

3.1

 

S

IGNALLING OVERVIEW

 ........................................................................ 19

 

3.2

 

C

ALLER AT THE DOOR

 .......................................................................... 19

 

3.3

 

R

ELAYS REGIMES

 ................................................................................ 21

 

3.4

 

P

ERSON IN THE BUILDING

 ..................................................................... 21

 

3.4.1

 

Outbound call ......................................................................................... 21

 

3.4.2

 

Incoming call .......................................................................................... 22

 

3.4.3

 

Door Entry System with keyboard – module SlimKey ............................. 22

 

4

 

PARAMETER PROGRAMMING ................................................................... 23

 

4.1

 

P

ROGRAMMING WITH THE HELP OF A PHONE

 ......................................... 23

 

4.1.1

 

Entry into the programming .................................................................... 23

 

4.1.2

 

Parameter programming ........................................................................ 23

 

4.2

 

P

ROGRAMMING WITH THE HELP OF A 

PC

 

 PROGRAMME 

B

RAVE

S

ET

 ...... 24

 

5

 

DESCRIPTION OF PROGRAMMABLE PARAMETERS .......................... 25

 

Содержание Brave series

Страница 1: ...Brave SlimDP 01 Brave SlimDP 02 Brave SlimDP 04 User and Service Manual Version 2 6 Brave Door Entry System...

Страница 2: ......

Страница 3: ...for the following options Brave SlimDP 01 1 button Brave SlimDP 02 2 buttons Brave SlimDP 04 4 buttons Basic functions of the new line Electronic volume control without the need to open the front cov...

Страница 4: ...me card panel 15 2 5 CONNECT THE KEYBOARD 16 2 6 CODE RELAY COSW 17 2 7 OTHER ACCESSORIES 18 2 7 1 Time Relay 18 2 7 2 Power supply 12V AC 18 2 7 3 Power supply 12V DC 18 2 7 4 USB Programming cable 1...

Страница 5: ...PARAMETERS 31 5 4 TIME PARAMETERS 33 5 5 SYSTEM PARAMETERS 37 5 6 BASIC SETTING AND DELETION 43 5 7 END OF PROGRAMMING 43 5 8 PARAMETER OVERVIEW 44 6 TECHNICAL PARAMETERS 47 6 1 ELECTRICAL PARAMETERS...

Страница 6: ...cure lock on the switch serial activation code COSW Option to disconnect a call by the repeated pressing of a button Option to switch on a baby call regime no number dialling Option to switch on a reg...

Страница 7: ...ignal is not available on an analogue line but the ringing tone ends and a connection begins It is difficult to identify the exact moment this occurs Code lock Function for relay connections by inputt...

Страница 8: ...s for all versions including any add on parameters for each version Available Features basic models Brave SlimDP 01 1 button Brave SlimDP 02 2 buttons Brave SlimDP 04 4 buttons Parameters that are not...

Страница 9: ...s supplied with a special key which is used to release the name cards on the front panel Push the key into the hole in the speaker grille see figure 1 2 Push the name card panel down and then push it...

Страница 10: ...d wood may require special screw types To power the unit for voice connect the telephone wires into the terminal on the right side Using either a standard analogue phone line or an analogue extension...

Страница 11: ...cuits on the board For the variants of lock connection see the picture below Wiring of standard and magnetic inverse lock 7 A special USB cable enables the doorphone to be connected to a PC for progra...

Страница 12: ...formed by ordinary phone DTMF tone dial The switch is The PCB heating has two major benefits Firstly it warms the board during winter time temperatures under 20 C most circuits have warranty operation...

Страница 13: ...where is a strong ambient noise at the phone and quiet environment at the communicator Here we leave the parameter value of 72 7 and 73 and 71 parameters set as follows parameter71 11 to 14 and 73 2...

Страница 14: ...trol and setting elements are located under the speaker front aluminium grille PC connector SlimDoorPhone fixing screw hole Service switch Loudspeaker Heating activation 12V for relay light and heatin...

Страница 15: ...ng 2 4 Final closing of Doorphone 2 4 1 Covering control elements 1 Push aluminium speaker cover back up see picture Take care when re covering the speaker The aluminium edge of the speaker may be gen...

Страница 16: ...possible control from phone during conversation too parameter 30 Code lock for relay in Doorphone from buttons stays conserved Connection by special cable is make that way will you use programming con...

Страница 17: ...Brave is set in several codes to activate the relay code Relay can be activated codes for one or two impulses can differentiate activated from the phone DTMF or from keys keyboard The last option is...

Страница 18: ...must be ordered separately Further details of power supplies and electric locks can be found at www alphatechtechnologies cz 2 7 3 Power supply 12V DC A 12V 1A DC alternative power supply is recommend...

Страница 19: ...rom the phone 800 Ticking during a call Notice about the end of a call 1333 Relay switch signal Modulated Entry into programming from the phone 980 1067 1180 Programming from the phone Modulated Param...

Страница 20: ...set in parameter 1 Following the repeated pressing of the same button when it detects a busy tone 10sec after choice or after a pre set number of rings parameter 56 the system dials a number from the...

Страница 21: ...of the button Any number of button other than in 311 3116 Button set in 311 or 312 3116 Note t1 time of connection of relay 1 parameter 371 t2 time between impulses of relay 1 parameter 301 Tab 1 Tabl...

Страница 22: ...o possible to input and a service password parameter 44 directing the system to go to the programming regime Another exception is during incoming call and DIP1 is switched to on SERVIS when the system...

Страница 23: ...et to put DIP switch to position off at the end 4 1 2 Parameter programming The default state for programming is announced with a programming tone the Brave always returns to this state after a specif...

Страница 24: ...ocedure Connect the Brave SlimDP to the line Connect Brave SlimDP to the PC via the USB cable The Brave will pick up a line and within 3 seconds a tone for programming entry will be heard see chapter...

Страница 25: ...of the first group or numbers of the regime Day Basic settings never change or delete these saved numbers Parameter Value Meaning Basic 2 tt nn number nn under button tt tt button number memory alway...

Страница 26: ...ding gates m 2 is switched on for time when the line is picked up camera switches on when system picks up and off when it disconnects m 3 is switched on for time when the line is picked up and extra t...

Страница 27: ...ght if the regime 2 groups of numbers is set the system is constantly in regime DAY There are several rules that needs to be followed when setting a password Choose the first button of password from b...

Страница 28: ...one there is an option to input a where a is a single number and the star represents an empty space and must be in the first place Switching a relay on with 2 impulses is used for sliding gates replac...

Страница 29: ...relay r 2 impulses time t2 01 99 105 205 r relay number relay number 1 in SlimDP 2 in Slimey zz time t2 between first and second impulse for switching on relay 1 2 spaces 00 99 where time 00 means 0...

Страница 30: ...0000 abcd Brave sends a serial code for the code relay COSW after evaluation code from keys keyboard namely for 2 pulses Parametr Value Description Default 3 4 abcd activation code 2 pulses from phone...

Страница 31: ...spaces 1 It is advantageous to set the same command for relay switching on parameter 35 36 and command for the Brave disconnection aa bb or aa cc 1 command is always 2 digits but if you wish to contr...

Страница 32: ...n the first place e g parameters 35 36 Note The Day Night switch over regime stays set following line disconnection Parameter Value Meaning Basic 47 e Regime system choice 0 1 1 e Choice of regime num...

Страница 33: ...the phone parameter 42 The setting of this time is in accordance with the adjacent table Parameter Value Meaning Basic 53 w Time between button presses 1 9 2 w maximum time in seconds between button...

Страница 34: ...hh then it will disconnect range 04 99 It repeats the choice if the regime of dialling 2 groups of numbers is set Parameter Value Meaning Basic 500 x Medium frequency of tone detector 1 0 3 375 475Hz...

Страница 35: ...is specified by the formulae the entered number x 10 time length of gap ms range 04 16 which is 40 160ms f Length of flash is specified by the formulae the entered number x 100 time length Flash ms ra...

Страница 36: ...DTMF 0 1 0 509 S Listening in DTMF level 1 4 2 p Preemphase is the ratio of the upper and lower groups of DTMF frequencies It is possible to choose ratio 2 2 dB p 0 Europe or ratio 3 2dB p 1 Australi...

Страница 37: ...z 2 Pick up and disconnection signalisation on intro concl type2 Parameter Value Meaning Basic 63 u Acoustic ticking signal during a call 0 1 0 Ticking during a call is switched off as standard Howeve...

Страница 38: ...irmation and a call is activated as if there were a number Warning During the first 10 seconds of a call the tone detector is inactive there is a pause before the switchboard responds or number dialli...

Страница 39: ...Siemens 0 1 0 This function is off as standard t 0 By switching this function on t 1 the processor goes into sleep mode immediately after the line connection and after 3 secs The Brave initialises Th...

Страница 40: ...nal for the end of a call If you don t press anything for 5 seconds then the set value is saved and you hear a confirmation tone WARNING Default values are set by the manufacturer and it is not recomm...

Страница 41: ...higher the sensitivity of the microphone In noisy surroundings it is recommended to use a higher value with combination of parameters 71 75 77 Parameter Value Meaning Basic 77 s Speed of switching ove...

Страница 42: ...sed by a conduit This function is switched off as standard k 0 but it is possible to set on 2 levels depending on the current that switchboard can supply short circuit current I0 Switchboard current I...

Страница 43: ...nly 4 85 Basic setting only for parameters 5x only 5 86 Basic setting only for parameters 6x only 6 87 Basic setting only for parameters 7x only 7 Parameters 81 and 82 deletes all numbers saved in the...

Страница 44: ...r 1 impulse 00 99 0 9 155 266 36 r cc command aa from the phone for switching on relay r 2 impulses 00 99 0 9 150 260 37 r ss time ss sec of relay r switch on for time t1 01 99 105 205 38 r p Control...

Страница 45: ...quency of tone detector 1 0 3 375 475Hz 501 y Number of busy tones 2 0 4 502 z Length of time for permanent tone 1 5 3 3s 503 tt Length of time for DTMF tone choice 04 16 10 100ms 504 mm Length of tim...

Страница 46: ...nd noise 0 1 1 76 b Threshold for switching on the microphone 1 4 4 is the highest 2 77 s Speed of switching over voice atomisation 1 4 is the slowest 2 78 l VA characteristic for line connection 0 1...

Страница 47: ...r min 10 25 V Impulse choice 40 60 ms Level of tone choice 6 a 8 dB 1 20 60 mA Sensitivity of tone choice min 40 dB 20 60 mA Sensitivity of tone detector min 30 dB 20 60 mA Power supply for name tag b...

Страница 48: ...2gr 202 24 Number under button 3 Night 2gr 203 24 Number under button 4 Night 2gr 204 24 Relay 1 works in mode m 1 6 311 1 Passw for relay 1 1 imp Day Night 3211 6 Passw for relay 1 1 imp Day Night 32...

Страница 49: ...code for activation 2 imp btn 0000 1111 3 3 4 code for activation 2 imp phn 0000 1111 3 4 4 code for activation other mode 0000 1111 3 5 4 Type of choice tone imp 0 1 41 1 Sign for prolonging of call...

Страница 50: ...ustic signalisation Intro Concl 0 1 62 1 Acoustic sign ticking 0 1 63 1 Signal tone turning on relay 0 1 65 1 Suppression of reception from microphone 0 1 66 1 Baby Call 0 1 67 1 Mute at the lock acti...

Страница 51: ...nt that warranty claims are handled through your dealer Warranty claims should be accompanied by The product in question A description of the problem Proof of purchase and Your full name and address T...

Страница 52: ...8 Drilling master board...

Страница 53: ...JR 2013 Version 2 6 X 13...

Отзывы: