26
BRAVE SlimDP
–
User and service manual
Note.
If you are not using regime Day/night or regime 2 groups of numbers, then it is
recommended to set regime Day/Night
(parameter 47)
and then set the same code
for switching over Day/Night
(parameters 45 and 46). His way it is guaranteed that
Brave will always be in Day regime and you can only programme telephone numbers
for the day regime
(parameter 1).
5.2 Relays
Parameter
Value
Meaning
Basic
31
r m
relay
r
operates in regime
m
(1-8)
11 21
r
– relay number [1 in SlimDP]
m
– relay regime [1-6
– not m=5
]
regimes
m=1, 4, 5, 6
are explained in detail in Relay Regimes Tab. 1 on page
21
m=1
mode
relay
– switched on with command (internal code) or with a
password (external) 1 impulse for length of time t1 (use for electric locks)
or 2 impulses when it switches on for time t1, off for t2 and again
switches on for t1 (opening of sliding gates).
m=2
is switched on for time when the line is picked up (
camera)
– switches on
when system picks up and off when it disconnects.
m=3
is switched on for time when the line is picked up and extra time t1 after
disconnection (
lights)
- switches on for time when the line is picked up
and extra time t1 after disconnection (for this time the line is busy)
m=4
regime
button
– switched on when any button is pressed and off after t1
(use is for example connection of external bell or siren)
m=6
switches on depending on pressed button (it is set in parameter 31r*). In
this way it is possible to choose only
one button
for each relay, which
when pressed switches on relay for time t1. This regime is used instead
of connecting separate doorbell to the system.
Parameter
Value
Meaning
Basic
31
r* tt
button tt switches on relay r in regime m=6
(01-04)
01
r
– relay number relay number [1 in SlimDP]
tt
– button number (memory), always in two digits [01-99]
This parameter is only for relay regime m=6. Value tt determines which button
starts switching on for time t1 of relay r.