Heatmaster 2
19
Temperature values
The values for “warning”, “alarm” and “emergency shutdown” can only be set with ascending temperature
values in this order. Hence it is not possible to monitor the system for undercutting of a certain bottom
temperature with this feature. Setting of an alarm or setting when undercutting a certain temperature is
possible with the “Online button / relay” feature though.
Pump / flow rate sensor configuration
Here the pump / flow rate sensor channel for which the settings are going to be made can be chosen.
Name
It is possible to set a name for every channel individually. The
name may contain up to 255 characters made up of letters and
numbers.
Status
Sets the status of the channel to: Off, not connected or On.
Type
Here the channel can be set to pump or flow rate sensor mode
Factor
This factor represents how many signals the pump / flow rate
sensor sends per revolution. Normal flow rate sensors have a
value of two. In rare cases or with different components this
factor may also be lower or higher. For pumps this value must
be determined by the user.
Pump settings
If a pump is connected, it can be monitored. Should the speed
of the pump undercut a certain value an “action in case of pump
failure” can be set. The choices are: No warning, alarm or
emergency shutdown
Flow rate sensor settings
If the conversion factor “Signals per liter” for the sensor is known, the unit can be set to “liters per hour” or
“Gallons per hour”. Similar to the temperature monitoring it is possible to set an action if a certain value is
undercut. Different values for warning, alarm an emergency shutdown can be set.