FIT THE CLOCK KIT - Fig. 16
Ensure the electrical supply to the boiler is isolated.
1.
Remove the two screws securing the clock cover at the rear of the control panel.
2.
Remove and discard the clock blanking panel.
3.
Insert the clock into the opening and secure in place with the screws supplied.
4.
Disconnect the clock wiring from the terminal block and connect it to the clock as follows:-
Blue wire to terminal 1, Brown wire to terminal 2 and Red wires to terminals 3 and 4, (or as per the instructions supplied with
the clock). Ensure wiring is correct.
5.
Replace the clock cover. Do not overtighten the fixing screws.
6.
Leave the control panel open until commissioning procedures have been completed.
Alpha CB50 - Installation
Fig. 16
Rear of control panel
Clock cover